11 Select the
Load Flash File
button to verify the
file is a .gff file.
Result: The following screen will be displayed.
12 Select the
Reprogram Device
(s) button to
start the ECM software update.
Result: The following screen will be displayed
after the software update is complete.
Note: Do not turn off power while the ECM is being
reprogrammed.
13 Select the
Run Application
button to exit the
software update mode.
14 Push in the red Emergency Stop button and
disconnect the CAT5 cable from the GCON.
15 Secure the diagnostic port cover using the
retaining fasteners removed in step 5. Do not
over tighten.
Note: Machines equipped with AGM batteries will
need to select the AGM battery type using the
GCON set parameters screen. Refer to the
Machine Setup
procedure in the Service and
Repair manual that is appropriate for your machine.
Tip over hazard. Updating the
SmartLink software may have
impacted the machines default
drive speeds. Tipping over the
machine will result in death or
serious injury.
Perform drive speed test. Refer
to the
Maintenance Manual
that
is appropriate for your machine.
16 Perform a function test. Refer to the
Operator's Manual on your machine.
17 Return the machine to service.