53
ReACT Pro
The added Penalty Time will have to be served before obtaining off-gassing credit begins again.
Once the Penalty Time is served and off-gassing credit begins, Required Stop Depths and Times
will decrease toward zero, then the Nitrogen Bar Graph will recede into the yellow Caution Zone
and the ReACT Pro will revert to the No Decompression Dive Mode.
DELAYED VIOLATION MODE
Three conditions will cause the ReACT Pro to enter a Delayed Violation Mode:
1. You remain above the Required Ceiling Stop Depth for 'more than 5 minutes'.
Total Ascent Time (TAT), the Stop Bar and NITROX symbols, and NiBG DECO segment, flash
(Fig. 58) until you descend below the Required Stop Depth. A single Long Beep will sound.
You would then need to follow the Stop Depths and Times toward the surface until the Nitrogen
Bar Graph recedes into the yellow Caution Zone.
2. Your necessary Decompression requires a Ceiling Stop Depth between 60 feet (18
meters) and 70 feet (21 meters).
Total Ascent Time (TAT), the Stop Bar symbol, the full NiBG, and graphic 60 will flash (Fig.
59) until you descend below the Required Stop Depth. One Beep per second will sound.
You must ascend to just deeper than 60 feet (18 meters), staying as close to 60 feet (18 meters) as
possible without causing Total Ascent Time (TAT) to flash. When the Required Stop Depth in-
dicates 50 FT (15 M), etc., you can ascend to, but no shallower than those depths and continue
decompressing.
Fig. 58 - Delayed Violation
(> 5 min above a Deco Stop)
Fig. 59 - Delayed Violation
(> 60FT/M Stop Required)
TAT
TAT
FT
FT
STOP
STOP
NITROX
E
D
O
D
E
C
TAT
TAT
FT
FT
STOP
STOP
NITROX
O
C
E
D
O
D
E
C
D
E
C
O
O
C
D
E
Flashing
Flashing
Flashing
Summary of Contents for React Pro
Page 1: ...OWNER S MANUAL OWNER S MANUAL React Pro...
Page 11: ...11 ReACT Pro FEATURES and DISPLAYS...
Page 21: ...21 ReACT Pro ACTIVATION and SETUP...
Page 31: ...31 ReACT Pro PRE DIVE and DIVE MODES...
Page 39: ...39 ReACT Pro POST DIVE MODES...
Page 47: ...47 ReACT Pro SPECIAL SITUATIONS...
Page 63: ...63 ReACT Pro CARE INSPECTION AND SERVICE...
Page 73: ...73 ReACT Pro REFERENCE...