© 2019 Genesis Attachments, LLC
Genesis GVP 07
30
SHEAR JAW SET MAINTENANCE
Weld with AWS E7018 electrode. Begin with the sides, filling in the chamfered area with single
passes, alternating sides and peening each pass. Weld the back and front following the same
method.
When welding is complete, grind the welds flush on each side.
Cycle the jaw slowly to check for interference.
Cover with heat blanket and allow to cool slowly.
DO NOT put unit into operation until cool.
Wear Plate Replacement
Important:
Remove the upper secondary blade during this procedure to prevent interpass tem-
perature.
Position and tack the new wear plate in place.
Weld with AWS E7018 electrode. Begin with the area between the wear plate and piercing tip.
Fill in the area with single passes, peening each pass. Weld the back and front following the same
method.
When welding is complete, grind the welds flush with the wear plate and piercing tip.
Cycle the jaw slowly to check for interference.
Cover with heat blanket and allow to cool slowly.
DO NOT put unit into operation until cool.