Rotator
Symptom
Possible Cause
Possible Solution
Does not rotate
Blown fuse
Replace fuse
Electrical problem
Test for proper voltage at plugs on
directional valve while depressing foot
switch
Incorrect pressure settings
Set pressures
Faulty components
Contact Genesis to replace valve
Does not rotate in one
direction
No electrical power to one side
Test for 12V at plugs on directional
valve while operating controller
Faulty directional control valve
Check if directional control valve shifts
both ways while actuating foot switch
in both directions
Faulty cartridge
Contact Genesis to replace valve
Rotator chatters
Electrical short
Check on VOM meter
Power to both rotation solenoids at
the same time
Test for 12V at plugs on directional
valve while operating controller
Rotates too fast or too
slow
Flow control out of adjustment
Set flow control
TROUBLE-SHOOTING GUIDE