Operation Manual for ZBL-R620/R630 Rebar Locator 

the  instrument  by  performing  a  number  of  tests  in  your  home  or  office,  prepare  simple 

scenarios which mimic onsite working environments. 

  Prepare  some  non-tensile  rebars  (use  the  two  thick  rebars  to imitate  the main  rebar, 

and use the thin rebars to imitate 

the top redar), plexiglass boards 

(or 

other 

non-ferromagnetic 

materials 

such 

as 

wooden 

board),  the  board  thickness  is 

about 25mm 

 Put the rebars on a plane and 

keep 

them 

away 

from 

ferromagnetic  materials.  Put  the 

plexiglass board over the rebars. (Fig. 1.4) 

 

2.1 System Connection 

 Connecting the Probe (Fig. 2.1) 

Insert the plug (black) of the signal 

line  into  the  socket  on  the  left  of  the 

rebar  locator,  rotate  clockwise  and 

lock  it  tightly  in  place.  Insert  the 

other  end  of  the  signal  line  into  the 

socket  on  the  probe  and  again  lock  it 

tightly.   

Note

There is no directional difference 

in the signal line. 

 

 

 

 Connecting the Scan Car

Fig. 2.2

(ZBL-R630 only) 

When inserting the scan car plug into its socket ensure to align the red dots, one on 

the apparatus with one on the signal line plug. 

Caution: When inserting or removing the cable be sure to hold the grip at the plug end of 

the cable, otherwise the wiring my become loose. 

Note

There is no directional difference in the signal line. 

 

                                                     

 Attach Scan Car (Fig. 2.3) (ZBL-R630 only) 

Correct 

Incorrect 

Fig. 2.2 connect with Scan Car 

Main rebar 

Top rebar 

Fig. 1.4 

Fig. 2.1

 

Summary of Contents for ZBL-R620

Page 1: ...ZBL R620 630 Rebar Locator Operation Manual...

Page 2: ...2 2 1 System Connection 3 2 2 Startup 4 2 3 System Reset 4 2 4 Choosing Scan Mode 5 2 5 Parameter Settings 5 2 6 Scan Operation 7 2 7 Data Display 10 2 8 Data Transmission 10 2 9 Deleting Data 12 2 1...

Page 3: ...ver and rebar diameter 1 2 Components of ZBL R620 R630 ZBL R620 R630 Rebar Locator is composed of a main instrument body a probe a scan car ZBL R630 only and signal transmission wire The probe has dir...

Page 4: ...erface Soft keyboard interface Fig 1 2 Menu Operation Interface The testing interface is used to scan data and display image including shown in Fig 1 3 General test scan Profile scan ZBL R630 only Gri...

Page 5: ...ig 2 1 Insert the plug black of the signal line into the socket on the left of the rebar locator rotate clockwise and lock it tightly in place Insert the other end of the signal line into the socket o...

Page 6: ...ry must be re charged If the automatic self test is OK it automatically enters the menu display after about five seconds Shortcuts in Main Menu interface key background light on off switch keys move c...

Page 7: ...ess highlight option Back key save current parameter setting return to previous menu and reset the system Menu key return to main menu interface Parameter amendment 1 General situation keys select the...

Page 8: ...and the interface automatically returns to the parameter setting interface 3 Thickness setting Set the concrete cover thickness of test rebar the available range is 10 99mm the initial value is automa...

Page 9: ...odes 1 General Test It is the basic scan mode of R630 It accurately measures the thickness of concrete cover and the diameter of rebar it may also judge if the component conforms to international stan...

Page 10: ...d the thickness is the lowest The central line of the probe is then the accurate location of the rebar Select the central location of the two rebars which have largest distance between each other as t...

Page 11: ...ing point unit cm will be displayed above the black dot The instrument automatically saves the test data and the image Press Back key return to parameter setting interface Press Menu key access the ma...

Page 12: ...ce move the cursor to data display option Press Enter to access the components list interface 2 In data display interface The left column shows the components list listed in descending order with the...

Page 13: ...ot recognized and the computer indicates that it has found new hardware device the user is directed to the appendix of R650 software operation manual for further advice 2 Computer operation Launch Reb...

Page 14: ...plays deleting 2 10 System Settings When accessing the system setting function the information below may be amended Fig 2 16 Date Year Month Day Time Hour Minute Second 24hours mode Power status may b...

Page 15: ...s signal cable is correct Check if the power is low battery power 0 3 3 No keypad tone Check system settings turn keyboard tones on then save settings If settings are normal but there are still no key...

Page 16: ...ndix A General Principles of Rebar Testing Scan surface should be smooth and flat If the surface is too rough to clean put a thin board on the scan surface after completing the scan the board s thickn...