Operation Manual for ZBL-R620/R630 Rebar Locator 

ZBL-R620/R630 Rebar Locator is designed for the measurement of concrete cover, 

bar diameters, rebars distribution and trend. 

 

1. General Introduction 

1.1 Basic Working Principles 

From its probe the apparatus emits an electromagnetic field into the interior of the test 

area,  and  then  receives  the  induced  magnetic  field  emitted  from  ferromagnetic  media 

such  as  rebars,  which  is  then  converted  into  an  electrical  signal.  The  main  instrument 

system allows real-time analysis and treatment of the electrical signal, displays the signal 

in  several  different  forms  such  as  image,  data,  and  sound  etc.  enabling  the  correct 

determination of rebar location, thickness of concrete cover, and rebar diameter. 

 

1.2 Components of ZBL-R620/R630 

ZBL-R620/R630 Rebar Locator is composed of a main instrument body, a probe, a 

scan car (ZBL-R630 only) and signal transmission wire. 

  The  probe  has  direction  sensitivity.  The  signal  is  strongest  when  the  probe  and  the 

rebar  directions  are  parallel,  on  the  contrary  the  signal  is  weakest  when  the  probe  and 

rebar directions are perpendicular to each other. 

 The scan car real-time correctly records the displacement of the probe.   

      Note:  when  measuring  with  the  scan  car,  it  is  better  to  move  the  car  in  a  smooth, 

uniform motion. 

 ZBL-R620/R630 Rebar Locator standard accessories (Fig. 1.1) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 1.1 Components of ZBL-R620/R630 Rebar Locator 

Scan Car     

(ZBL-R630 only) 

Universal Probe 

Signal Cable 

Scan Car connection 

Back 

Menu 

Save 

Confirm 

Up 

On / Off Switch 

Left 

Screen 

Right 

Down 

Power socket 

Indicator light 

USB Port 

Scan  Car  connection 

port 

Probe  connection 

port 

Battery housing 

Summary of Contents for ZBL-R620

Page 1: ...ZBL R620 630 Rebar Locator Operation Manual...

Page 2: ...2 2 1 System Connection 3 2 2 Startup 4 2 3 System Reset 4 2 4 Choosing Scan Mode 5 2 5 Parameter Settings 5 2 6 Scan Operation 7 2 7 Data Display 10 2 8 Data Transmission 10 2 9 Deleting Data 12 2 1...

Page 3: ...ver and rebar diameter 1 2 Components of ZBL R620 R630 ZBL R620 R630 Rebar Locator is composed of a main instrument body a probe a scan car ZBL R630 only and signal transmission wire The probe has dir...

Page 4: ...erface Soft keyboard interface Fig 1 2 Menu Operation Interface The testing interface is used to scan data and display image including shown in Fig 1 3 General test scan Profile scan ZBL R630 only Gri...

Page 5: ...ig 2 1 Insert the plug black of the signal line into the socket on the left of the rebar locator rotate clockwise and lock it tightly in place Insert the other end of the signal line into the socket o...

Page 6: ...ry must be re charged If the automatic self test is OK it automatically enters the menu display after about five seconds Shortcuts in Main Menu interface key background light on off switch keys move c...

Page 7: ...ess highlight option Back key save current parameter setting return to previous menu and reset the system Menu key return to main menu interface Parameter amendment 1 General situation keys select the...

Page 8: ...and the interface automatically returns to the parameter setting interface 3 Thickness setting Set the concrete cover thickness of test rebar the available range is 10 99mm the initial value is automa...

Page 9: ...odes 1 General Test It is the basic scan mode of R630 It accurately measures the thickness of concrete cover and the diameter of rebar it may also judge if the component conforms to international stan...

Page 10: ...d the thickness is the lowest The central line of the probe is then the accurate location of the rebar Select the central location of the two rebars which have largest distance between each other as t...

Page 11: ...ing point unit cm will be displayed above the black dot The instrument automatically saves the test data and the image Press Back key return to parameter setting interface Press Menu key access the ma...

Page 12: ...ce move the cursor to data display option Press Enter to access the components list interface 2 In data display interface The left column shows the components list listed in descending order with the...

Page 13: ...ot recognized and the computer indicates that it has found new hardware device the user is directed to the appendix of R650 software operation manual for further advice 2 Computer operation Launch Reb...

Page 14: ...plays deleting 2 10 System Settings When accessing the system setting function the information below may be amended Fig 2 16 Date Year Month Day Time Hour Minute Second 24hours mode Power status may b...

Page 15: ...s signal cable is correct Check if the power is low battery power 0 3 3 No keypad tone Check system settings turn keyboard tones on then save settings If settings are normal but there are still no key...

Page 16: ...ndix A General Principles of Rebar Testing Scan surface should be smooth and flat If the surface is too rough to clean put a thin board on the scan surface after completing the scan the board s thickn...

Reviews: