Operation Manual for ZBL-R620/R630 Rebar Locator 

 

Second scan updates scan data only, doesn’t update the rebar’s distribution image. 

   

 

 

 

 

 

 

 

 

 

The second scan operation introduced above is the normal operation, users don’t 

need to scan every adjacent bar, instead a cross-bar scan is performed. For the Cross-bar 

scan a single bar in the x-direction and a single bar in the y-direction are selected for use 

during a second-scan operation. In order to use Windows software analysis the operator 

is required to record the separation between the parallel test lines of the first and second 

scans. For queries related to the use of the Windows software, the reader is directed to 

the R650 software operation manual. 

 

2.7 Data Display 

Display the saved component, data and image 

1) In Menu interface, move the cursor to “data display” option. 

  Press 

Enter

to access the “components list” interface 

2) In data display interface 

The left column shows the “components list”, listed in descending order with the newest at 

the  top.  The  right  column  shows  the  “data  display”  area,  displaying  the  statistical 

information of saved data for the current concrete element. 

 

【↑

↓】

keys, move cursor to the concrete element you want to select.   

 

【←

  ,

→】

keys,  allow  movement  to  the  next  or  previous  pages  of  “concrete 

elements menu” shown in the left column of the screen; 

  Press 

Menu

key, return to main menu. 

Press 

Enter

key to access the data display interface, the screen displays data or image 

(profile, grid).   

 

【↑

↓】

key,  allow  movement  to  previous  or  next  page in  up-down direction 

(profile or grid scan mode); 

 

【 ←

  ,

→ 】

key,  allow  movement  to  previous  or  next  image  in  left-right 

direction(profile or grid scan mode). 

 

2.8 Data Transmission 

Using data transmission any data saved within the appliance can be transferred to an 

Fig. 2.9 

Fig. 2.10 

Summary of Contents for ZBL-R620

Page 1: ...ZBL R620 630 Rebar Locator Operation Manual...

Page 2: ...2 2 1 System Connection 3 2 2 Startup 4 2 3 System Reset 4 2 4 Choosing Scan Mode 5 2 5 Parameter Settings 5 2 6 Scan Operation 7 2 7 Data Display 10 2 8 Data Transmission 10 2 9 Deleting Data 12 2 1...

Page 3: ...ver and rebar diameter 1 2 Components of ZBL R620 R630 ZBL R620 R630 Rebar Locator is composed of a main instrument body a probe a scan car ZBL R630 only and signal transmission wire The probe has dir...

Page 4: ...erface Soft keyboard interface Fig 1 2 Menu Operation Interface The testing interface is used to scan data and display image including shown in Fig 1 3 General test scan Profile scan ZBL R630 only Gri...

Page 5: ...ig 2 1 Insert the plug black of the signal line into the socket on the left of the rebar locator rotate clockwise and lock it tightly in place Insert the other end of the signal line into the socket o...

Page 6: ...ry must be re charged If the automatic self test is OK it automatically enters the menu display after about five seconds Shortcuts in Main Menu interface key background light on off switch keys move c...

Page 7: ...ess highlight option Back key save current parameter setting return to previous menu and reset the system Menu key return to main menu interface Parameter amendment 1 General situation keys select the...

Page 8: ...and the interface automatically returns to the parameter setting interface 3 Thickness setting Set the concrete cover thickness of test rebar the available range is 10 99mm the initial value is automa...

Page 9: ...odes 1 General Test It is the basic scan mode of R630 It accurately measures the thickness of concrete cover and the diameter of rebar it may also judge if the component conforms to international stan...

Page 10: ...d the thickness is the lowest The central line of the probe is then the accurate location of the rebar Select the central location of the two rebars which have largest distance between each other as t...

Page 11: ...ing point unit cm will be displayed above the black dot The instrument automatically saves the test data and the image Press Back key return to parameter setting interface Press Menu key access the ma...

Page 12: ...ce move the cursor to data display option Press Enter to access the components list interface 2 In data display interface The left column shows the components list listed in descending order with the...

Page 13: ...ot recognized and the computer indicates that it has found new hardware device the user is directed to the appendix of R650 software operation manual for further advice 2 Computer operation Launch Reb...

Page 14: ...plays deleting 2 10 System Settings When accessing the system setting function the information below may be amended Fig 2 16 Date Year Month Day Time Hour Minute Second 24hours mode Power status may b...

Page 15: ...s signal cable is correct Check if the power is low battery power 0 3 3 No keypad tone Check system settings turn keyboard tones on then save settings If settings are normal but there are still no key...

Page 16: ...ndix A General Principles of Rebar Testing Scan surface should be smooth and flat If the surface is too rough to clean put a thin board on the scan surface after completing the scan the board s thickn...

Reviews: