SC800 T3 Operation
SC800 T3 Diagnostics Screen
076R160-000
SpectraComm 800 T3 Data Service Unit
3-15
Issue 4
Installation and Operation Manual
SC800 T3 Diagnostics Screen
At the SC800 T3 Main Menu, press
2
and then press
Enter
to access the Diagnostics screen,
shown below.
describes the screen selections.
Note
If the loopback test requires cooperation with an operator at a remote site, contact that person and make
arrangements to perform the test. Tests that must be initiated (and then terminated) at both sites include the
End-to-End Self-Test, Network Line and Payload Loopbacks
Note
Refer to Chapter 5, Diagnostics for test procedures and data path diagrams for each test.
Table 3-8
Diagnostics Screen Selections
Selection
Description / Settings
[1] Loopback Test
Selections are: Stop Test/No Test (default), Line Loopback, Payload
Loopback, Local Loopback, Local Loopback w/ST, DTE Loopback,
Remote Lineloop, Remote Lineloop w/ST, Remote Payldloop, Remote
Payldloop wST
[2]
Test Time Limit
30 seconds (default) or 1-10 in 1 minute intervals or 10 to 30 minutes
in 5 minute intervals, or unlimited.
[3] Transmit DS3 Idle
Active or Inactive (default) - Sends the standard DS3 Idle signal
(11001100...) to the network.
[4] Reset Test results
Resets Diagnostic Results and Bit Errors so you can run another test.
[5] Insert 1-Bit Error
Use this command to insert a single bit error to verify test results.