Figure III: Construction Equipment
1. In seat box
2. On rear wall
3. In a protective case outside
Figure IV: Truck
1. In passenger footwell
2. On cabin rear wall
3. In the toolbox
4. Under the bed
Installation: Angle
All positions suggested are examples. Other locations
are possible so long as they correspond to the proper
installation guidelines and requirements.
Figure V: Position Angles
1. Heater air intake
2. Glow pin position
3. Direction of air flow
Figure V shows the ideal installation position of the
heater; with exhaust pointing downward. Depending
on its location it can be tilted by 30° with the air flow
and hot air outlet facing the bottom. It can also be
tilted on its longitudinal axis by 90° so long as the
glow pin position points upward. During usual
operation the heater can deviate by 15° each way
with vehicle movement without impaired function of
the heater.
Wiring Harness Connector Positions
The main connector coming off the heater can be
moved to the other side of the heater if necessary. In
order to do so, you must first remove the air inlet grill