Alternatively, to fit the digital timer, simply fit the 

appropriate screw inside the hole located at the 
center of the timer. Both plug into the corresponding 

black and clear plugs on the loom. 

Controller Connections 

The controllers are best installed in a manner that 
they can be seen and operated easily to identify 

working conditions and also for easy access. The 
black and clear plugs connect to the corresponding 

plugs on the loom (below). The remaining three-pin 

socket on the timer or rheostat control plugs into the 
remote control receiver if one is installed. An adaptor 

cable may be necessary. 

Digital Timer Connections 

 

 

Analog Controller Connections 

 

 

Wire Harness Connections 

 

 

Ambient Temperature Sensor 

The external temperature sensor plugs into the 

corresponding blue and brown wired socket on the 

diagram and should ideally by mounted at shoulder 
height when sat down to ensure correct reading of 

the air temperature. It should not be mounted in 
such a way as to obstruct air flow; like up high, in the 

corner of the vehicle cabin or above heat sources. 

NOTE 

Only one controller can be used at a time. 

NOTE 

Any surplus wires should be kept in good 
condition and wrapped in electric tape to 
avoid short circuiting. 

UNUSED 

BLUE/WHITE 

 

BLUE 

BLACK 

BROWN 

RED/YELLOW

 

GRAY 

UNUSED 

RED/WHITE 

 

UNUSED 

BLUE 

BLACK 

BROWN 

RED/YELLOW

 

GRAY 

RED 

BLUE/WHITE 

RED/WHITE 

BLACK 

BLUE 

RED/YELLOW 

 

BROWN 

RED 

GRAY 

Summary of Contents for BISON 2200A

Page 1: ...BISON 2200A OWNER S MANUAL...

Page 2: ...k Continued 9 Exhaust System 9 Combustion Air Intake 9 Installation Fuel Lines 10 Installation Fuel Line Connectors 10 Installation Fuel Line Length and Order 11 Installation Fuel Pump Angle 11 Instal...

Page 3: ...nd exhaust do not get blocked by other objects Take care to ensure that the exhaust outlet is installed in a way that prevents fumes from entering the vehicle or are discharged in the direction of the...

Page 4: ...utput Selection Adjustable Min to Max Air Circulation Ventilation No Heat Fan Only Dimensions LxWxH Inches mm 12 21 x 4 53 x 4 80 310 x 115 x 122 Weight lbs kg 5 95 2 7 1 2 3 4 5 6 7 8 9 10 11 12 13 1...

Page 5: ...ar trunk space Figure II Minivan 1 In front of the passenger seat 2 Between driver s and passenger s seat 3 Under the vehicle s floor 4 Under the rear seat 5 In rear trunk space 30 130 60 310 25 24 13...

Page 6: ...ideal installation position of the heater with exhaust pointing downward Depending on its location it can be tilted by 30 with the air flow and hot air outlet facing the bottom It can also be tilted...

Page 7: ...tion then simply replace the lid and grill back in position Installation Mounting The chosen mounting surface should be flat and you will need to drill the appropriate size hole for the exhaust combus...

Page 8: ...2 Ensure that the mounting surface is flat and smooth 3 The mounting gasket supplied must be fitted 4 Mounting plate should be used to even out the roughness of the surface 5 M6 Washer 6 M6 Nut Instal...

Page 9: ...ole system should also point downwards and if necessary a 5mm hole should be drilled near the bottom to drain off any condensation You should also route the exhaust so that the fumes are not taken bac...

Page 10: ...sure all connectors are fastened securely to prevent dripping of fuel particularly onto hot surfaces or electrical components Installation Fuel Line Connectors When connecting fuel lines into rubber c...

Page 11: ...Pump Angle Installation Fuel Tank Head See next page for legend 1 3 2 4 5 6 7 8 9 1 Fuel Tank 6 Fuel Filter 2 Fuel Pick up Tube 7 Fuel Pump 3 Fuel Connector Clamp 8 Fuel Pump Damper 4 Fuel Line 9 Hea...

Page 12: ...is will make it easier to attach the nut securely back onto the pick up tube Drill a 6 0 2mm hole into the sender unit Remove the nut from the pick up tube and feed it through the hole ensuring the ru...

Page 13: ...e necessary Digital Timer Connections Analog Controller Connections Wire Harness Connections Ambient Temperature Sensor The external temperature sensor plugs into the corresponding blue and brown wire...

Page 14: ...Page 14 of 19 Electrical Diagram...

Page 15: ...ermostatic mode the heater will then switch to a cool down cycle automatically once it has reached the selected temperature The fan button only switches the fan on for cool air Operation Digital Timer...

Page 16: ...pressing OK until back to the P1 menu screen 8 Press power button to return The language will now be set to English Changing Date and Time 1 To change the date and time navigate to the clock symbol an...

Page 17: ...three individual start times per day on any combination of seven days 1 Navigate to P symbol and press OK 2 Using the arrow keys select the number 1 flashing and the top of the screen and press OK num...

Page 18: ...ller will flash a fault code The controller should therefore be ideally placed where it can be clearly seen and accessed The faults will be displayed as short flashes followed by long flashes To deter...

Page 19: ...C0235 Upper Casing GC0236 Lower Casing GC0238 Outer Hood GC0334 Fuse GC0335 Fuse GC0611 Analog Control GC0653 Digital Control Switch GC0654 Digital Control Switch GC0695 Analog Controller with GSM Rec...

Reviews: