Page 13 of 19
Alternatively, to fit the digital timer, simply fit the
appropriate screw inside the hole located at the
center of the timer. Both plug into the corresponding
black and clear plugs on the loom.
Controller Connections
The controllers are best installed in a manner that
they can be seen and operated easily to identify
working conditions and also for easy access. The
black and clear plugs connect to the corresponding
plugs on the loom (below). The remaining three-pin
socket on the timer or rheostat control plugs into the
remote control receiver if one is installed. An adaptor
cable may be necessary.
Digital Timer Connections
Analog Controller Connections
Wire Harness Connections
Ambient Temperature Sensor
The external temperature sensor plugs into the
corresponding blue and brown wired socket on the
diagram and should ideally by mounted at shoulder
height when sat down to ensure correct reading of
the air temperature. It should not be mounted in
such a way as to obstruct air flow; like up high, in the
corner of the vehicle cabin or above heat sources.
NOTE
Only one controller can be used at a time.
NOTE
Any surplus wires should be kept in good
condition and wrapped in electric tape to
avoid short circuiting.
UNUSED
BLUE/WHITE
BLUE
BLACK
BROWN
RED/YELLOW
GRAY
UNUSED
RED/WHITE
UNUSED
BLUE
BLACK
BROWN
RED/YELLOW
GRAY
RED
BLUE/WHITE
RED/WHITE
BLACK
BLUE
RED/YELLOW
BROWN
RED
GRAY
Summary of Contents for BISON 2200A