Cleaning and maintenance
•
25
Cleaning and maintenance
Note:
Regular and conscientious maintenance increases the service life of
the OptiFeed B FPS19 Fresh powder system and provides for a
longer continuous coating quality!
The parts, which are to be replaced during maintenance work, are
available as spare parts. These parts will be found in the
corresponding spare parts list!
Daily maintenance
1. Empty the powder hose by removing the fluidizing/suction unit
from the powder container when the conveying is activated
2. Clean the powder hose; Please also review the section "Color
change"
Weekly maintenance
1. Visual check of the pinch valves in the OptiFeed PP06 Powder
pump for possible damages
Note:
For further information, see the OptiFeed PP06 Powder pump
operating manual!
2. Clean the fluidizing/suction unit The fluidizing/suction unit is
placed back into the powder shortly before restarting operation
3. Check the Fresh powder system grounding connections to the
coating booth, the suspension devices of the work pieces, or the
conveyor chain
If in disuse for several days
1. Interrupt the power supply/remove the mains plug
2. Clean the Fresh powder system thoroughly