Cleaning and maintenance
OptiFeed B FPS19
Cleaning
WARNING
If no dust mask or one of an insufficient filter class is worn when
cleaning the Fresh powder system, then the dust that is stirred up
from the coating powder can cause respiratory problems.
- The ventilation system must be turned on for all cleaning work.
- A dust mask corresponding to filter class FFP2 at minimum must
be worn during any cleaning work.
Cleaning the fluidizing/suction unit
-
Remove the powder pump from the fluidizing/suction unit
-
Remove the fluidizing/suction unit
-
Clean the fluidizing/suction unit with compressed air. Blow off
the suction tube also with compressed air
-
Visual check of the fluidizing/suction unit for possible
damages
-
Reassemble the individual parts and reinsert the fresh
powder pump
Maintenance and cleaning of the filter unit
The filter unit on the OptiFeed 2 S Fresh powder system measures and
cleans the compressed air. This is where the equipment's main
compressed air connection is located.
Replacing the filter element
Procedure:
1. Unscrew the filter glass on the filter unit
2. Remove the complete filter element
3. Replace the filter element
4. Clean the filter glass on the inside and install it again