V12/19
iONstream 4.0
Electrical Connection
•
29
Use in standalone operation
Standalone operation occurs without the use of a communication
interface. For use of an individual neutralization bar, simply connect the
24 VDC power supply protected by the fuse (for value, refer to “Technical
Data”). The system runs according to the factory settings or, in individual
cases, according to the ordered system values.
WARNING
Explosion hazard
► In stand-alone operation, the connection to the power supply of
the ionizers must be carried out outside the explosive area (zone)
by means of the stand-alone cable to prevent the risk of ignition.
IMPORTANT for system status detection:
– Machine speed > 0 m/min.
= 24 VDC ON
– Machine STOPP
= 24 VDC OFF
Factory settings
HV frequency range to
100 Hz
max. output voltage
6 kV, 12 kV or 18 kV
Operating mode
AUTO
DC
Clean Bar Warning
at 40% efficiency loss
Clean Bar Alarm
at 60% efficiency loss
The pulse pause length is set automatically between 50/50 and 90/10 as
this is AUTO
DC
technology depending on the external field so that the best
possible discharge is achieved.