V12/19
32
•
Electrical Connection
iONstream 4.0
8
Worn tips (wear &
tear)
This mode displays the emitter pin status. The pin sharpness has
reached the set limit value for abrasion of the pins due to wear / age
(factory setting = 80 %)
The system efficiency has dropped from 100 % to below 80 % without
contamination / after the bar has been cleaned.
9
Timeout
The external residual charge sensor cannot be found. This function is
only active when the FEEDBACK mode is activated and an iONsense
4.0 sensor is connected.
10
Failure
This mode shows that the discharge system has detected an error and
is not functioning. Within a network, the error code can be read using the
iONmaster, iONgate or iONlink.
11
Unconfigured
This mode shows that the BUS subscriber has no NODE-ID and no
application parameters are saved. This mode only occurs when the
NODE-ID has been deleted or the factory settings were not saved.
12
Start up
In this state, the system waits for 1 sec for a "Speed Message" or a CAN
"hard-beat". If there is no BUS available, the system automatically
switches to the initialization state and activates the discharge.
13
Check Installation
This mode shows that the discharge electrode has been installed to
close to a ground / machine ground.