V12/19
iONstream 4.0
Safety Instructions
•
13
During neutralizing bar cleaning
WARNING
Danger of electric shock
► Always disable the 24 VDC power supply when cleaning the
neutralizing bars.
Caution!
Sharp pins
Grounding
WARNING
Danger of electric shock
► The iONstream neutralizing systems
MUST
be grounded.
In problem situations
ATTENTION
If liquid has been spilled on the bar, disable 24 VDC power immediately.
Correct the problem before restarting the machine.
WARNING
Danger when using uncertified systems
Never use iONstream neutralizing systems in explosive environments if
they are not Ex-Certified.
► also refer to version table
► Ex-Certified bars have an ATEX Ex label attached to the bar
profile.
Ozone generation
Ozone may be generated when the iONstream is in use.
This phenomenon and its concentration depend on several
parameters. It is not possible to specify a common figure of the ozone
concentration during usage.
– If the ozone concentration becomes an issue at a specific
workstation, on-site measurement has to be taken and
adequate ventilation must be provided.