9.2.8 Flange connection EN 1092
ØL
ØD
øk
H1
FTF
Connection types
code
1)
8
Material
code
2)
8
17, 18,
39, 83
C3
40, 42 8, 17, 18,
39, 40,
42, 83
C3
MG
DN
øD
øk
øL
n
H1
H1
H1
H1
FTF
FTF
25
15
95.0
65.0
14.0
4
19.0
18.0
13.0
19.0
130.0
150.0
20
105.0
75.0
14.0
4
19.0
20.5
16.0
19.0
150.0
150.0
25
115.0
85.0
14.0
4
19.0
23.0
19.0
19.0
160.0
160.0
40
32
140.0
100.0
19.0
4
28.0
28.7
24.0
26.0
180.0
180.0
40
150.0
110.0
19.0
4
28.0
33.0
26.0
26.0
200.0
200.0
50
50
165.0
125.0
19.0
4
35.0
39.0
32.0
32.0
230.0
230.0
n = number of bolts
1)
Connection type
Code 8: Flange EN 1092, PN 16, form B, face-to-face dimension FTF EN 558 series 1, ISO 5752, basic series 1, length only for body configur-
ation D
2)
Valve body material
Code 8: EN-GJL-250 (GG 25)
Code 17: EN-GJS-400-18-LT (GGG 40.3), PFA lined
Code 18: EN-GJS-400-18-LT (GGG 40.3), PP lined
Code 39: 1.4408, PFA lined
Code 40: 1.4435 (F316L), forged body
Code 42: 1.4435 (BN2), forged body, Δ Fe < 0.5%
Code 83: EN-GJS-400-18-LT (GGG 40.3), hard rubber lined
Code C3: 1.4435, investment casting
GEMÜ 649 eSyDrive
www.gemu-group.com
27 / 48
9 Dimensions
Summary of Contents for 649 eSyDrive
Page 24: ...9 2 5 www gemu group com 24 48 GEM 649 eSyDrive 9 Dimensions...
Page 26: ...9 2 7 www gemu group com 26 48 GEM 649 eSyDrive 9 Dimensions...
Page 30: ...10 www gemu group com 30 48 GEM 649 eSyDrive 10...
Page 37: ...www gemu group com 37 48 GEM 649 eSyDrive 15 6 15 Electrical connection...