8.6 Electrical data
Supply voltage:
Actuator size 0
Actuator size 1
Actuator size 2
Voltage
Uv = 24 V DC ± 10%
Rating
Max. 28 W
Max. 65 W
Max. 120 W
Operating mode
(OPEN/CLOSE opera-
tion)
Continuous duty
Operating mode (con-
trol operation)
Class C acc. to EN 15714-2
Reverse battery protec-
tion
Yes
8.6.1 Analogue input signals
8.6.1.1 Set value
Input signal:
0/4 - 20 mA; 0 – 10 V DC (selectable using software)
Input type:
passive
Input resistance:
250 Ω
Accuracy/linearity:
≤ ±0.3% of full flow
Temperature drift:
≤ ±0.1% / 10°K
Resolution:
12 bit
Reverse battery protec-
tion:
No
Overload proof:
Yes (up to ± 24 V DC)
8.6.1.2 Process actual value
Input signal:
0/4 - 20 mA; 0 – 10 V DC (selectable using software)
Input type:
passive
Input resistance:
250 Ω
Accuracy/linearity:
≤ ±0.3% of full flow
Temperature drift:
≤ ±0.1% / 10°K
Resolution:
12 bit
Reverse battery protec-
tion:
No
Overload proof:
Yes (up to ± 24 V DC)
8.6.2 Digital input signals
Digital inputs:
3
Function:
selectable using software
Voltage:
24 V DC
Logic level "1":
>14 V DC
www.gemu-group.com
16 / 48
GEMÜ 649 eSyDrive
8 Technical data
Summary of Contents for 649 eSyDrive
Page 24: ...9 2 5 www gemu group com 24 48 GEM 649 eSyDrive 9 Dimensions...
Page 26: ...9 2 7 www gemu group com 26 48 GEM 649 eSyDrive 9 Dimensions...
Page 30: ...10 www gemu group com 30 48 GEM 649 eSyDrive 10...
Page 37: ...www gemu group com 37 48 GEM 649 eSyDrive 15 6 15 Electrical connection...