External fuses of the Power Section DC input side
Use the following fuses when a Line Regen converter is used.
230 … 400 Vac, 50Hz
Fuses
2040
Z14GR16
A70P20-1
FWP20A14F
2055
Z14GR20
A70P20-1
FWP20A14F
2075
Z14GR32
A70P30-1
FWP30A14F
3110
Z14GR40
A70P40-4
FWP40B
3150
Z22GR63
A70P60-4
FWP60B
4185 - 4221
S00C+/üf1/80/80A/660V
A70P80
FWP80
4301
S00C+/üf1/80/100A/660V
A70P100
FWP100
4371
S00C+/üf1/80/125A/660V
A70P150
FWP150
5450
S00C+/üf1/80/160A/660V
A70P175
FWP175
5550
S00üF1/80/200A/660V
A70P200
FWP200
6750
S1üF1/110/250A/660V
A70P250
FWP250
7900
S1üF1/110/315A/660V
A70P350
FWP350
71100
S1üF1/110/400A/660V
A70P400
FWP400
71320
81600
82000
S1üF1/110/600A/660V
A70P600
FWP600
fusibili dc-g
S1üF1/110/500A/660V
A70P500
FWP500
Type
460 Vac, 60Hz
Fuses
Chokes / Filters
Note!
A three-phase inductance should be connected on the AC Input side in order to limit the input RMS current of
the Drives. The inductance can be provided by an AC Input choke or an AC Input transformer.
Mains
inductance
Rated
current
Saturation
current
Freq.
[mH]
[A]
[A]
[Hz]
2040
1.63
8.7
18
50/60
LR3y-2040
2 (4.4)
EMI FFP 480-24
1.4 (3.1)
-
-
2055
1.29
11.8
24.5
50/60
LR3y-2055
2.2 (4.4)
EMI FFP 480-24
1.4 (3.1)
EMI-C 480-25
0.96 (2.1)
2075
0.89
17.4
36.5
50/60
LR3y-2075
4.9 (10.8)
EMI FFP 480-24
1.4 (3.1)
EMI-C 480-25
0.96 (2.1)
3110
0.68
22.4
46.5
50/60
LR3y-3110
5 (11)
EMI FFP 480-30
1.6 (3.5)
EMI-C 480-25
0.96 (2.1)
3150
0.51
30
61
50/60
LR3y-3150
6.2 (13.7)
EMI FFP 480-40
2.3 (5.1)
-
-
4185
0.35
41
83
50/60
EMI 480-45
1.3 [2.9]
-
-
4221
0.35
41
83
50/60
EMI 480-45
1.3 [2.9]
-
-
4301
0.24
58
120
50/60
LR3-030
9.5 (20.9)
EMI 480-70
2.6 [5.7]
-
-
4371
0.18
71
145
50/60
LR3-037
9.5 (20.9)
EMI 480-70
2.6 [5.7]
-
-
5450
0.13
102
212
50/60
EMI 480-100
2.6 [5.7]
-
-
5550
0.13
102
212
50/60
EMI 480-100
2.6 [5.7]
-
-
6750
0.148
173
350
50/60
EMI 480-150
4.4 [9.7]
-
-
7900
0.148
173
350
50/60
EMI 480-180
4.4 [9.7]
-
-
71100
0.085
297
600
50/60
EMI 520-280
28 (61.7)
-
-
71320
0.085
297
600
50/60
EMI 520-280
28 (61.7)
-
-
81600
0.085
297
600
50/60
EMI 520-450
45 (99.2)
-
-
82000
0.085
380
710
50/60
LR3-200
54 (119)
EMI 520-450
45 (99.2)
-
-
indutt-filtri-g
LR3-090
55 (121.3)
LR3-160
44 (97.0)
Type
3-Phase AC Input Chokes
EMI filters, class (*)
EMI filters, class (**)
Model
Weight
kg (lbs)
Model
Weight
kg (lbs)
Model
Weight
kg (lbs)
LR3-022
7.8 (17.2)
LR3-055
12.5 (27.6)
(*): EN61800-3, 1st environment restricted distribution.
(**) Class A, for drive/motor cable 5 meters max length.
Summary of Contents for SIEIDrive LIFT AGy -L
Page 1: ... Instruction manual SIEIDrive LIFT Lift vector AC Drives AGy L ...
Page 46: ...Italiano 46 AGy L ...
Page 90: ...English 90 AGy L ...
Page 134: ...Français 134 AGy L ...
Page 178: ...Deutsch 178 AGy L ...
Page 222: ...Español 222 AGy L ...
Page 240: ...NOTE ...
Page 241: ......