228
AGy -L
LCD Display
DESCRIPTION
LCD Selection
Description
Def.
Min
Ma
x
Un
it
Va
ri
at
.
IPA
PARAMETER
PICK LIST
C
ode
[6] DI 5
The command comes from
DigInp5
[7] DI 6
The command comes from
DigInp6
[8] DI 7
The command comes from
DigInp7
[9] DI 8
The command comes from
DigInp8
[10] DI Exp 1
The command comes from ExpDI
1
[11] DI Exp 2
The command comes from ExpDI
2
[12] DI Exp 3
The command comes from ExpDI
3
[13] DI Exp 4
The command comes from ExpDI
4
[14] AND 1
The command comes from the
output of the block AND1
[15] AND 2
The command comes from the
output of the block AND2
[16] AND 3
The command comes from the
output of the block AND3
[17] OR 1
The command comes from the
output of the block OR1
[18] OR 2
The command comes from the
output of the block OR2
[19] OR 3
The command comes from the
output of the block OR3
[20] NOT 1
The command comes from the
output of the block NOT1
[21] NOT 2
The command comes from the
output of the block NOT2
[22] NOT 3
The command comes from the
output of the block NOT3
[23] NOT 4
The command comes from the
output of the block NOT4
[24] FrqSel match The command is coming from the
output of the block Freq Sel
match
[25] ShortFloorFl
The command is the short floor
flag
I.001
Run Fwd src
Source of the Run Forward command of LCW
As for I.000
3
0
25
101
I.002
Run Rev src
Source of the Run Reverse command of LCW
As for I.000
4
0
25
102
I.003
Freq Sel 1 src
Source of the Frequency Selector 1 of LCW
As for I.000
5
0
25
103
I.004
Freq Sel 2 src
Source of the Frequency Selector 2 of LCW
As for I.000
6
0
25
104
I.005
Freq Sel 3 src
Source of the Frequency Selector 3 of LCW
As for I.000
7
0
25
105
I.006
Freq Sel 4 src
Source of the Frequency Selector 4 of LCW
As for I.000
0
0
25
106
I.007
Ramp Sel 1 src
Source of the Ramp Selector 1 of LCW
As for I.000
25
0
25
107
I.008
Ramp Sel 2 src
Source of the Ramp Selector 1 of LCW
As for I.000
0
0
25
108
I.009
Ext fault src
Source of the External Fault command of LCW
As for I.000
8
0
25
109
I.010
Faul reset src
Source of the Fault Reset command of LCW
As for I.000
9
0
25
110
I.011
Bak pwr act src
Source of the Backup Power Supply Active command of LCW
As for I.000
0
0
25
111
I.012
Forced stop src
Source of the Forced Stop command of LCW
0
0
25
185
I.100
Dig output 1 cfg
Digital output 1 configuration
[0] Drive Ready
51
0
55
112
[1] Alarm state
[2] Not in alarm
[3] Motor run
[4] Motor stop
[5] REV rotation
[6] Steady state
[7] Ramping
[8] UV running
Summary of Contents for SIEIDrive LIFT AGy -L
Page 1: ... Instruction manual SIEIDrive LIFT Lift vector AC Drives AGy L ...
Page 46: ...Italiano 46 AGy L ...
Page 90: ...English 90 AGy L ...
Page 134: ...Français 134 AGy L ...
Page 178: ...Deutsch 178 AGy L ...
Page 222: ...Español 222 AGy L ...
Page 240: ...NOTE ...
Page 241: ......