236
AGy -L
LCD Display
DESCRIPTION
LCD Selection
Description
Def.
Min
Ma
x
Un
it
Va
ri
at
.
IPA
PARAMETER
PICK LIST
C
ode
P.501 Sw freq reduc en
Enabling of switching frequency reduction
[0] Disable
0
0
1
483
[1] Enable
P.502 Min switch freq
Minimum switching frequency
As for P.500
(*)
0
P.500
495
P.520 Overmod max lev
Overmodulation level
0
0
100
%
1
484
P.540 Out Vlt auto adj
Automatic adjustment of output voltage
1
0
1
485
P.560 Deadtime cmp lev
Dead times compensation limit
(*)
0
255
486
P.561 Deadtime cmp slp
Dead times compensation slope
(*)
0
255
487
P.580 Startup display
IPA of the parameter to be displayed at power on
8
1
1999
488
P.600 Speed dsply fact
Speed conversion constant for display
10.00
0.01
99.99
0.01
489
P.998 Param access lev
Access level
2
1
3
499
P.999 Param prot code
Parameters protection code
0 Protection disabledStopped motor: possibility to
write all parameters.
Running motor: some
parameters are writing protected
(IPA in bold)
0
0
3
490
1 Protection
enabled
(*) = only with
motor stopped
All parameters are writing
protected excepted:
- F000, F100..F116, multispeed
function parameters
- P999 Param prot code
- C000 Save parameter (*)
- C020 Alarm clear
- H500..H511, serial line
commands.
2 Protection
enabled
(*) = only with
motor stopped
All parameters are writing
protected excepted:
- P999 Param prot code
- C000 Save parameter (*)
- C020 Alarm clear
- H500..H511, serial line
commands.
3 Protection disabledStopped motor: possibility to
write all parameters.
Running motor: some
parameters are writing protected
(IPA in bold)
Possibility to execute Save
parameter also with running
motor.
A.000 PID mode
PID mode
[0] Disable
Null
0
0
6
1200
[1] Freq sum
PID out in sum with ramp out ref
(Feed forward)
[2] Freq direct
PID out not in sum with ramp out
ref (no Feed forward)
[3] Volt sum
PID out in sum with voltage ref
from V/f curve (Feed forward)
[4] Volt direct
PID out not in sum with voltage
ref from V/f curve (no Feed
forward)
[5] Stand alone
PID function as generic control
(only with drive in RUN)
[6] St-Al always
PID function as generic control
(any drive status)
A.001 PID ref sel
PID reference selector
[0] Null
Null
0
0
7
1201
[1] Analog inp 1
Analog input 1
APPLICATION
Summary of Contents for SIEIDrive LIFT AGy -L
Page 1: ... Instruction manual SIEIDrive LIFT Lift vector AC Drives AGy L ...
Page 46: ...Italiano 46 AGy L ...
Page 90: ...English 90 AGy L ...
Page 134: ...Français 134 AGy L ...
Page 178: ...Deutsch 178 AGy L ...
Page 222: ...Español 222 AGy L ...
Page 240: ...NOTE ...
Page 241: ......