238
AGy -L
LCD Display
DESCRIPTION
LCD Selection
Description
Def.
Min
Ma
x
Un
it
Va
ri
at
.
IPA
PARAMETER
PICK LIST
C
ode
C.000 Save parameters
Save parameters command
(1)
No action.
(1)
(1)
(2)
800
(2)
Save parameters command.
C.001 Recall param
Recall last set of saved parameters
(1)
No action.
(1)
(1)
(2)
801
(2)
Recall last set of saved
parameters.
C.002 Load default
Recall of the factory parameters.
(1)
No action.
(1)
(1)
(2)
802
(2)
Load default parameters.
C.020 Alarm clear
Reset of the the Alarm List register
(1)
No action.
(1)
(1)
(2)
803
(2)
Clear alarm register command.
C.040 Recall key prog
(1)
No action.
(1)
(1)
(2)
804
(2)
Recall parameter from PRG-KEY
key.
C.041 Save pars to key
(1)
No action.
(1)
(1)
(2)
(2)
Storage of parameters to PRG-
KEY key.
C.050 Rst mdplc prec run
(1)
No action.
(1)
(1)
(2)
809
(2)
Reset mdplc error
C.060 Calculate space
(1)
No action.
(1)
(1)
(2)
809
(2)
Start
C.070 Recall kbg prog
(1)
No action.
(1)
(1)
(2)
809
(2)
Recall pars from keypad
C.071 Save pars to kbg
Storage of parameters into LCD keypad
(1)
No action.
(1)
(1)
(2)
810
(2)
Store pars into keypad
C.100 Measure stator R
Motor Autotune command
(1)
No action.
(1)
(1)
(2)
806
(2)
Autotune command.
H.000
Virtual digital command
0
0
255
1000
H.001
Exp virtual digital command
0
0
255
1001
H.010
Virtual digital state
0
0
255
1002
H.011
Exp Virtual digital state
0
0
255
1003
H.020
Virtual An Output 1
0
-32768 32767
1004
H.021
Virtual An Output 2
0
-32768 32767
1005
H.022
Exp Virtual An Output 1
0
-32768 32767
1006
H.030
Profidrive Control word (see Profibus instruction manual)
0
0
65535
1007
H.031
Profidrive Status word (see Profibus instruction manual)
0
0
65535
1008
H.032
Profidrive reference (see Profibus instruction manual)
0
-16384 16383
1040
H.033
Profidrive actual reference (see Profibus instruction manual)
1
-16384 16383
1041
H.034
Drive status
0
0
65535
1042
H.040
Progress
0
0
100
1009
H.050
Drive output frequency at 32bit (LSW) (d.000)
0
- 2
31
2
31
-1
1010
H.051
Drive output frequency at 32bit (MSW) (d.000)
0
- 2
31
2
31
-1
1011
H.052
Drive reference frequency at 32bit (LSW) (d.001)
0
- 2
31
2
31
-1
1012
H.053
Drive reference frequency at 32bit (MSW) (d.001)
0
- 2
31
2
31
-1
1013
H.054
Output speed (d.000)*(P.600) at 32bit (LSW) (d.007)
0
- 2
31
2
31
-1
1014
H.055
Output speed (d.000)*(P600)at 32bit (MSW) (d.007)
0
- 2
31
2
31
-1
1015
H.056
Speed Ref (d.001)*(P.600) at 32bit (LSW) (d.008)
0
- 2
31
2
31
-1
1016
H.057
Speed Ref (d.001)*(P.600) at 32bit (MSW) (d.008)
0
- 2
31
2
31
-1
1017
H.058
Encoder freq at 32bit (LSW) (d.301)
0
- 2
31
2
31
-1
1018
H.059
Encoder freq at 32bit (MSW) (d.301)
0
- 2
31
2
31
-1
1019
H.060
Encoder speed (d.000)*(P.600) at 32bit (LSW) (d.302)
0
- 2
31
2
31
-1
1044
H.061
Encoder speed (d.000)*(P.600) at 32bit (MSW) (d.302)
0
- 2
31
2
31
-1
1045
H.062
Bitwise reading of active alarms (bit 0 to 15). Each bit is
associated to a specific alarm, according to table 9.3.1.
0
0
2
31
-1
1060
This menu is not available on the keypad. The setting and the reading of the parameters here contained, can be performed exclusively via serial line or through SBI card.
805
Storage of the inverter parameter on the external key
Recall of parameters from LCD keypad
HIDDEN
Reset mdplc error at previous run
Off line space evaluation
COMMAND
Recall of the parameters in the external key
Summary of Contents for SIEIDrive LIFT AGy -L
Page 1: ... Instruction manual SIEIDrive LIFT Lift vector AC Drives AGy L ...
Page 46: ...Italiano 46 AGy L ...
Page 90: ...English 90 AGy L ...
Page 134: ...Français 134 AGy L ...
Page 178: ...Deutsch 178 AGy L ...
Page 222: ...Español 222 AGy L ...
Page 240: ...NOTE ...
Page 241: ......