HyTronic Service Handy, Unidirectional
Operation
B
577
-00
2
&BDC © 05
-20
0
8
WC controls
Commands
Menu item
[EN]
[DE]
Description
Application
Setting range
Factory
setting
20
[FullFlush]
[VollMenge]
Release the full flush volume.
Function test
Start = "OK"
-
21
[PartFlush]
[TeilMenge]
Release the partial flush
volume.
Function test
Start = "OK"
-
22
[RangeTest]
[TestErfas]
Check detection range.
Red LED in the sensor starts
glowing when an object enters
the detection range. No flush is
released (reset after 10
minutes).
Problems with the user
detection
Deactivation = [0]
Detection of
person=[1]
Detection of
manual actuation
= [2]
Detection of B-
sensor = [3]
-
23
[BlocFlush]
[Blockiere]
Block flush.
Command blocks the control
so that no flush can be released
(reset after 10 hours).
a) Carry out repair works
b) Deactivate control
On = "OK"
Off = "OK"
Off
24
[FactrySet]
[Werkeinst]
Factory settings.
All settings are restored to
factory settings
Problems with the settings
-
-
Programs
Menu item
[EN]
[DE]
Description
Application
Setting range
Factory
setting
30
[ManFlshEn]
[FreiManSp]
Enable manual touchless flush.
Program enables / disables
manual flush.
Problems with manual flush
On = [ON]
Off = [OFF]
On = [ON]
31
[IntFlush]
[IntervSp]
Select interval flush.
The control automatically
releases a flush within the set
interval.
a) Hygiene
b) Flushing out of stagnant
water
c) Drying out of odour trap
1 - 168 hours
24 hours
168 hours
32
[PowOnFlsh]
[NetzEinSp]
Select power-on flush.
Program activates/deactivates
flush after power failure.
a) Function test
b) Hygiene
On = [ON]
Off = [OFF]
Off [OFF]
33
[PreFlush]
[Vorspülng]
Select pre-flush.
Program activates / deactivates
short flush when object enters
detection range.
Hygiene
On = [ON]
Off = [OFF]
Off [OFF]