HyTronic Service Handy, Unidirectional
Operation
B
577
-00
2
&BDC © 05
-20
0
8
Washbasin taps
Commands
Menu item
[EN]
[DE]
Description
Application
Setting range
Factory
setting
20
[Valve]
[Ventil]
Switch valve.
Flushes until turned off (closes
automatically after 10 minutes).
a) Function test of the valve
b) Flushing out of stagnant
water
On = "OK"
Off = "OK"
Off
21
[RangeTest]
[TestErfas]
Check detection range.
Red LED in the sensor starts
glowing when object enters
detection range. No flush is
released (turns off automatically
after 90 seconds).
Problems with the user
detection
On = "OK"
Off = "OK"
Off
22
[FactrySet]
[Werkeinst]
Factory settings.
All settings are restored to
factory settings
Problems with the settings
-
-
Programs
Menu item
[EN]
[DE]
Description
Application
Setting range
Factory
setting
30
[MainProgr]
[Hauptmenü]
Select main menu.
Attendance: Flushes as long as
an object is in the detection
range.
Singapore: Water turns off after
3 seconds.
Select one of the two
programs.
Attendance =
[OFF]
Singapore = [ON]
Attendance
Settings
Menu item
[EN]
[DE]
Description
Application
Setting range
Factory
setting
40
[RunOnTime]
[NachlaufZ]
Set run-on time.
Tap keeps on flushing
according to entered value after
an object has left the detection
range.
a) Hygiene
b) Cleaning of implements
0 - 2 seconds
0 seconds
41
[SafetyT]
[AbschaltZ]
Set safety time.
Limiting flow duration
Safety switch-off function
40 seconds = [4]
50 seconds = [5]
60 seconds = [6]
40 seconds
[4]
42
[SensorOps]
[Sensoren]
Set sensor beams.
Improving detection
Both on = [0]
Lower on = [1]
Upper on = [2]
Both on [0]