Settings
Menu item
[EN]
[DE]
Description
Application
Setting range
Factory
setting
40
[DetectT]
[VerweilZ]
Set detection time.
Sets the minimum detection
time that is necessary to
release the flush.
1 - 60 seconds
7 seconds
41
[DelayTime]
[Spülverzö]
Set flush delay.
Sets the time between leaving
the detection range and starting
the flush.
1 - 15 seconds
3 seconds
42
[CleanTime]
[ReiniZeit]
Set cleaning time.
Sets the time during which the
control is inactive in cleaning
mode.
1 - 30 minutes
10 minutes
43
[DetectRng]
[Erfassdis]
Set the detection distance.
Individual adjustment of the
detection distance
Short = [0]
Long = [1]
Short [0]
Counters
Menu item
[EN]
[DE]
Description
Output
50
[Days?]
[SumBetrT?]
Total number of days of operation.
Displays the number of days of operation since commissioning.
Days
51
[Uses?]
[SumBenut?]
Total number of uses.
Displays the number of uses since commissioning.
Uses
52
[Flushes?]
[SumSpül?]
Total number of flushes / valve switchings.
Displays the number of flushes / valve switchings since commissioning.
Flushes / switchings
53
[AutFlush?]
[SumAutSp?]
Total number of automatic flushes.
Displays the number of automatic flushes since commissioning.
Flushes
54
[ManFlush?]
[SumManSp?]
Total number of manual flushes.
Displays the number of manual flushes since commissioning.
Flushes
55
[IntFlush?]
[SumIntSp?]
Total number of interval flushes.
Displays the number of interval flushes since commissioning.
Flushes
56
[PreFlush?]
[SumVorSp?]
Total number of pre-flushes.
Displays the number of pre-flushes since commissioning.
Flushes