7
2014-10 · Flow Diversion Device with Proximity switch
Inlet Port
Divert Port
⇒
to Balance Tank
Function
„Divert Flow“ position
The „Divert Flow“ position is the start position of the
valve after assembling in which the divert valve routes
the product back to the balance tank during periods of
sub-legal pasteurization temperatures.
The valve position is detected by a sensors installed in
the control module. The interface module with two sen-
sors to determine the valve position is installed in the
control module. The sensors determine the valve posi-
tion and the interface module generate the correspond-
ing feedback signals and send them to the master con-
trol system (see operating instructions of the control
module T.VIS M-1 FDD).
Divert Valve
Leak Detect Valve