12
2014-10 · Flow Diversion Device with Proximity switch
Commissioning
• Clean the valve assembly prior to the first production
run.
Functional test
• Actuate each valve of the Flow Diversion Device once
by applying compressed air.
• Prior to the first product run clean the pipe system.
Leak test
• Visually check that all seals are free from leaks.
• Replace defective seals.
Malfunction, Cause,
Remedy
CAUTION
In the event of malfunctions immediately deactivate the
Flow Diversion Device and secure it against inadvertent
reactivation. Defects may only be rectified by qualified
personnel observing the safety instructions.
The following applies to each valve in the Flow
Diversion Device.
Malfunction
Cause
Remedy
Valve does
Error in the
Check the plant
not work
control system
configuration
No compressed
Check the
air air
supply
Air pressure
Check the air
too low
hoses for free
passage and
leaks
Error in the
Check actuation
electric system
/external controller
and routing
of electric lines
Solenoid valve
Replace the
defective
solenoid valve
Valve does
Dirt/foreign
Clean the valve
not close
materials between housing and
valve seat and
the valve seat
valve disk
Valve closes
O-rings dry
Grease the O-rings
too slowly
in the actuator
and in the control
module
(friction losses)
Leakage at the O-rings in the
Dismantle the
valve housing housing
valve housing,
defective
replace the O-rings
Leakage in the Sealing ring
Replace the sealing
lantern
defective
ring
Maintenance
Inspections
Between the maintenance periods, the each valve of the
Flow diversion devices must be checked for leakage and
proper function.
Product contact seals
• Check at regular intervals:
– stem seal between the upper housing and the lantern
– O-rings between the valve housings
– V-ring in the valve disks
Pneumatic connection
• Check the operating pressure at the pressure reducing
and filter station.
• Clean the air filter in the filter station at regular inter-
vals.
• Check whether the air hose sits firmly in the air con-
nector.
• Check the air hoses for bends and leaks.
• Check function of the solenoid valves.
Electrical connection
• Check whether the cap nut on the cable gland is tight.
• Check the cable connections at the adapter module.
• Check function of the solenoid valves.