18
2014-10 · Flow Diversion Device with Proximity switch
1
2
DANGER
There is a danger of injury when the spring-opening valve
is assembled. Therefore, do not put your hand in the valve
housing. Before unscrewing the valve disk, pretension the
actuator using an emergency manual actuator (H) (part no.
221.310.74).
Assemble the valve in the reverse sequence of disassembly.
During assembly, observe the following instructions:
• Lock the spacer nut (2) against the actuator rod (1).
• Tighten the nuts of the clamps at the control module with
a torque of 1 Nm.
• Tighten the nuts of the hinged clamps with following
torques:
M 6
9 Nm
M 8
22 Nm
• Tighten the nuts of the cast-semi-annular clamps with a
torque of 45 Nm (33 lbft).
Checking the valve stroke
• Actuate the valve by applying compressed air.
• Check whether the valve stroke (c) is correct.
Valve size
Valve stroke c (mm)
OD 1"
15
OD 1
1/2
"
23
OD 2"
30
OD 2
1/2
"
30
OD 3"
30
OD 4"
30
OD 6"
60
• Check the function of the feedback or sensors and, if nec-
essary, readjust them (see operating instructions Control
Module T.VIS M-1 FDD).
C