20
2014-10 · Flow Diversion Device with Proximity switch
Tools / Lubricant
Tool
Part no.
Pneum. emergency switchbar DN 25...100 221-105.67
Pneum. emergency switchbar
DN 125...162 (6" IPS)
221-105.65
Emergency manual actuator
221.310.74
Strap wrench
408-142
Hose cutter
407-065
V-ring insertion tool
229-109.88
Open spanner, ends ground, size 17-19
229-119.01
Open spanner, ends ground, size 21-23
229-119.05
Open spanner, ends ground, size 22-24
229-119.03
Open spanner, size 30-32
408-041
Allen key size 3 and 8
Screw driver torx 10 IP
Screw driver torx 20 IP
Phillips head screw driver size 2
Slotted screw driver A 0.4 X 2.5
Open spanner size 13
Spacer 0.059 inches
221-105.32
Lubricant
Part no.
Rivolta F.L.G. MD-2
413-071
PARALIQ GTE 703
413-064
Disposal of valve actuators
DANGER
When actuators are opened, the prestressed spring can
cause loss of life.
The spring tension can be as much as 24 kN. Therefore
never try to force the actuator open. Only deactivated
actuators may be scrapped.
✗
GEA Tuchenhagen accepts unopened actuators and
arranges for proper disposal free of charge.
Technical Data
Size
1" to 6" OD
Weight
20 to 164 kg, depending on
size and equipment
Material of product
stainless steel 1.4404
contact parts
Check corrosion resistance
with respect to media and
detergents.
Installation position
any position, if valve and
pipe system can drain
properly
Ambient temperature
0...45 °C, standard
Valve
< 0 °C: use control air with
low dew point. Protect
valve stems against freezing
> +60 °C: no solenoid valves
in the control module
Interface module
−
20...+70 °C
with sensors
Product temperature and depending on the sealing
operating temperature
material
Product pressure
5 bar, standard
max. 10 bar
Control air pressure
6 bar, max. 8 bar, standard
< 6 bar on request
Control air
acc. to ISO 8573-1:2001
– Solid particle content: quality class 6
particle size max. 5 μm
part. density max. 5 mg/m
3
– Water content:
quality class 4
max. dew point +3 °C
If the valve is used at
higher altitudes or at low
ambient temperatures,
the dew point must be
adapted accordingly.
– Oil content:
quality class 3,
preferably oil free
max. 5 mg oil in 1m
3
air
Air hose
Inch
material PA
outside dia. 6,35 mm
inside dia. 4,3 mm
Protection class
IP 66, IP 67 on option
Noise level
72 dB max
via sound absorber