Special hazardous spots
DANGER
In the event of malfunctions set the Flow diversion
device out of operation (disconnect the valve from the
power and the air supply) and secure it against reacti-
vation.
Immediately rectify the fault.
Never put your hand into the lantern (2) or into the
valve housing (4).
When the hinged clamps at the actuator (1) or at the
housing (3) of the non-actuated valve (spring-closing
action) are detached, there is danger of injury, since the
released spring pressure suddenly lifts the actuator (5).
Therefore, prior to detach ing the hinged clamps, release
the spring tension by
– the pneumatic emergency switchbar
or
– pressurizing the actuator with compressed air.
CAUTION
Housing sockets have very sharp edges. Therefore wear
suitable protection gloves during transport or installa-
tion of the Flow diversion devices.
For transportation of the valve, it is imperative to
remove the control module and the valve stem and to
use the screwed-in eye bolt (R), part no. 221-104.98 for
lifting the valve.