10.4
Prior to disassembly
Requirement:
•
Make sure that during maintenance and servicing work no process is in
operation in the area concerned.
Carry out the following steps:
1.
Drain all pipe system elements that lead to the valve and, if necessary, clean
or rinse them.
2.
Shut off the control air supply.
3.
Disconnect the power supply.
4.
Take the valve out of the pipe section, with all housings and housing
connections if possible.
®
Done
10.5
Disassembling Valve X
10.5.1 Manually lift valve X
Fig.10
Requirement:
•
No solenoid valve must be actuated electrically or manually.
•
The pneumatic and electrical connections on the plant side can remain on the
control top.
Spring-closing valve
Maintenance
Prior to disassembly
430BAL008430EN_4
08.03.2022
39