Residual dangers on the valve and measures
Danger
Cause
Measure
Danger to life
Inadvertent switch-on of the
valve
Effectively disconnect all components, effectively prevent switch-
on.
Electric power
Observe the following safety rules:
1.
Isolate from the power supply.
2.
Take appropriate measures to prevent switch on.
3.
Test absence of voltage.
4.
Earthing and short-circuiting.
5.
Cover or safeguard any adjacent live parts.
Spring tension in the actuator
Danger to life caused by compression spring in the actuator. Do
not open the actuator but return it to GEA Tuchenhagen for
proper disposal.
Danger of injury
Danger presented by moving or
sharp-edged parts
The operator must exercise caution and prudence.
For all work:
•
Wear suitable work clothing.
•
Never operate the machine if the cover panels are not
correctly fitted.
•
Never open the cover panels during the operation.
•
Never reach into openings.
As a precautionary measure, wear personal protective equipment
in the vicinity of the valve:
•
Protective gloves
•
Safety shoes
Environmental damage
Operating materials with
properties which are harmful to
the environment
For all work:
•
Collect lubricants in suitable containers.
•
Dispose of lubricants in accordance with the pertinent
regulations.
Safety
Residual dangers
430BAL008430EN_4
08.03.2022
15