10.4.13 Installing the single mechanical seal - spring encapsulated (hygiene)
0433.00
Fig.69:
Single hygienic mechanical seal
0433.00 mechanical seal
Features
–
Encapsulated spring
–
Sealing towards the impeller
–
Easy to clean
–
For adhesive media
–
Optimal arrangement in the pump chamber
Equipment and tools from the GEA Hilge assembly tool kit:
•
Spray bottle
•
Plastic mounting sleeve
Prior to installation
1.
Check the shaft and counter ring holder for impurities and damage (sharp
edges). If necessary, clean or replace parts.
Fig.70:
Shaft and counter ring holder
A - Counter ring holder | B - Fixed ring of the mechanical seal (counter ring)
Notice!
Hygiene risk, food safety
Danger due to contamination
► Carefully inspect the seat of the mechanical seal.
► Pay attention to groove and pin for mechanical seal with anti-twist
protection.
Malfunctions / repairs
Repair
BA.H2A.ADY.002.GB_1
74
18.12.2017