10.4.12 Installing single conical spring mechanical seal
Equipment and tools from the GEA Hilge assembly tool kit
•
Spray bottle
•
Plastic mounting sleeve
•
Mounting sleeve
Installing single conical spring mechanical seal
Wet the fixed ring (counter ring) of the mechanical
seal (0433.00) and the shaft (0211.00) with clean
water.
Fig.64:
Fixed ring of the
mechanical seal
Push the counter ring of the mechanical seal
(0433.00) into the seat of the back plate (0161.00).
Fig.65:
Set ring
Push the mounting sleeve onto the shaft shoulder.
Moisten the mounting sleeve with clean water.
HILGE assembly tools prevent damage to the
mechanical seal during further assembly.
Fig.66:
Mounting sleeve
Malfunctions / repairs
Repair
BA.H2A.ADY.002.GB_1
72
18.12.2017