Installing ADAPTA bearing support size 3
Push the V-rings (0507.02) and (0507.05) with
greased sealing lips from both sides onto the shaft
(0211.00) so that the sealing lips contact the
bearing caps (0360.00/01).
Fig.45:
V-rings
Insert the feather key (0940.01) into the shaft
(0211.00).
Do not use a mallet! The bearings could be
damaged.
Fig.46:
Feather key
Grease the coupling seat on the shaft (0211.00)
with Klüber paste UH1 96-402.
Fig.47:
Coupling seat
Check the coupling inserts (0867.02) for wear and
replace if necessary.
Push the coupling half (0840.00) onto the shaft
(0211.00) so that it is flush with it.
Fig.48:
Coupling half
Malfunctions / repairs
Repair
BA.H2A.ADY.002.GB_1
18.12.2017
65