Description
Technical Data
2007-9015-001
03-2014
3.6.4
Control panel specifications
The control panel must:
● comply with the following requirements:
- 2006/95/CE directives (Electrical equipment designed for use within
certain voltage limits)
- 92/31/CEE directives (Electromagnetic compatibility)
● comply with the following harmonized standards:
- EN 60204-1 (Safety of machinery - Electrical equipment of machines);
- EN 61082-1 (Documents used in electrotechnology);
- EN 60617 (Graphical symbols).
● be equipped with an emergency stop.
● be protected by a lockable disconnect switch (cut-off switch).
● meet all motor specifications provided in this manual.
● meet local electrical requirements.
Special specifications:
● The control panel protection devices must be designed to avoid any
unexpected start.
3.6.5
Lubricant specifications
Lubricant
Type
Brands / Specifications
Purpose
Hydraulic oil
Use these brands (or equivalent)
● Petro-Canada AW 32
● Shell Tellus 32
● Exxon Nuto H32
● Mobil AW Hydraulic Oil 32
Fill Hydraulic Power
Unit tank.
Fill Insulated gate
valve tube.
Biodegradable
oil
Required specifications:
● Kinematic Viscosity
60-100 cSt @ 40°C [100°F]
● Pour point:
below -10°C [14°F]
● Oil must not contain any
additives that may damage
piston gasket.
Lubricate piston
pump seal.
General
Purpose
Grease
Use these brands (or equivalent)
● EP2 mineral grease
Lubricate the
equipment.