Description
Main View
2007-9015-001
03-2014
Hydraulic guillotine valve (optional)
Hydraulic cylinder
Hydraulic cylinder hose
adaptors
Hydraulic guillotine control valve
Selection valve
Hydraulic cylinder hose adaptors
Pump and tank hoses
Reversing valve
hoses
Flapper valves
Note!
The flapper valve prevents manure flow back as long as manure
remains consistent enough to seal the flapper. The flapper valve may
leak if manure becomes watery, or if a piece of material gets stuck
between the flapper and the valve housing. The flapper valve should
be preceded by a gate valve to ensure that the evacuation line can be
shut off in case of emergency.
The flapper valve is a check valve
attached to the end of the evacuation
line to prevent manure from flowing
back into the evacuation line.
Available for 12-¾ ” [315 mm] or 16” [406
mm] evacuation lines.