Safety instructions
Dangerous situations during assembly can be avoided by safety-conscious and
proactive behaviour of the staff.
For installation, the following principles apply:
•
Only properly qualified staff is allowed to install, assemble and set the valve
into operation.
•
Ensure that adequate working and traffic areas are available at the place of
installation.
•
Observe the maximum load-bearing capacity of the installation surface.
•
Observe the transport instructions and markings on the part(s) to be
transported.
•
Remove any nails protruding from transport crates immediately after opening
the crate.
•
Under no circumstances should anyone stand under a suspended load.
•
During assembly, the valve safety devices might not be working effectively.
•
Reliably secure sections of the plant which have already been connected
against inadvertently being switched on.
6.2
Notes on installation
The valve must be installed so that the housing can drain on its own.
To prevent damage, make sure that
•
the valve is installed in the pipe system free of tension and
•
no foreign materials (e.g. tools, bolts, lubricants) are left in the system.
•
the valve is installed so that the flow is directed against the valve disc.
•
the valve is ideally installed in vertical position.
6.3
Welding In a Valve with Pipe Connection
6.3.1
Welding In and Installing a Valve
This section describes how you weld in a valve with pipe connection.
Prerequisite:
•
For valves with welding ends: Actuator and internal assembly have been
removed, see Section 10.6, Page 38.
Assembly and installation
Safety instructions
430BAL012727EN_1
24
03.01.2018
Summary of Contents for Aseptomag GD