Compressed air supply
Compressed air supply
6 bar, compressed air filtered (at least 0,5 µm), oil-free.
Cleaning
Cleaning
The valve is suitable for CIP cleaning (Cleaning in Place)
Recommended cleaning speed
in the valve
At least 2 m/s
Sterilisation
Sterilisation
The valve is suitable for SIP sterilisation (Sterilisation in Place)
Sterilisation with
Hot water, max. 160 °C (320 °F)
Steam, max. 160 °C (320 °F)
Chemicals (e.g. H
2
O
2
)
5.2
Determination of closing pressure
The closing pressure effective at the valve seat during operation can be
calculated approximately. It is mandatory, however, that the fine adjustment at
the valve must be carried out on site.
Tools required:
•
Specification of the supplied air pressure.
•
Specification of the valve-specific regulation ratio (see design documentation);
the ratio between the drive cross-section FL1 and the valve seat cross-section
FL2 (FL1/FL2).
FL1
FL2
Fig.8:
Cross-sections relevant to regulation ratio.
Carry out the following steps:
Technical data
Determination of closing pressure
430BAL012727EN_1