6
Setting the Program
Choosing a program:
3
3
3
3
3
1)
Press NEXT three times until
“START TIME”
flashes on screen. Press ENTER.
2)
Press the UP and DOWN arrows to set the hour.
Press ENTER.
3)
Press the UP and DOWN arrows to set the minute.
Press ENTER.
Note: Select a time that water usage is not expected in the
dwelling. (e.g. 2:00 a.m.)
Setting Flush/Drain Time
2
2
2
2
2
FIGURE 3
Low Turbidity:
Less than 0.5 NTU
Medium Turbidity:
Peaks to 1.0 NTU, less than 72 min.
per day.
High Turbidity:
Peaks to 5.0 NTU, less than 72 min. per
day.
Very High Turbidity:
Peaks to 10.0 NTU, less than 72
min. per day.
NOTE: If surface water is the source and the Surface
Water Option Kit is installed, select either Program 3 or
Program 4 in this application.
1)
Press NEXT four times until
“PROGRAM”
flashes on screen.
2)
Press ENTER.
3)
Press the UP and DOWN arrows to set the
Program number. Select the appropriate Program
for your application. Press ENTER.
FIGURE 4
Setting the Flush/Drain Interval:
4
4
4
4
4
FIGURE 5
Note: Under conditions of turbid water and high usage of
the System, select a Flush/Drain Interval setting
appropriate to the specific application. Increase
frequency of flush/drain cycle if the System TMP rises too
quickly. Increasing the number of Flush/Drain cycles per
day will prolong the life of the System; however, more
water will be used for system cleaning purposes.
Flush / Drain
Interva l
Setting
No. of
Flush/Dra in
Cycle s pe r
Day
Tim e Inte rval
Be tw ee n
Flush/Dra in Cycle s
t:01
once
24 hours
t:02
2 times
12 hours
t:04
4 times
6 hours
t:08
8 times
3 hours
t:24
24 times
1 hour
1) Press NEXT five times until “
t:01
” appears on
screen.
2) To change the flush/drain interval setting, hold
the UP and DOWN arrows down
together
and
press NEXT. Release all buttons and repeat to
shift to the next interval. There are five interval
settings to choose from:
Low
Turb idity
P rogram 1
M ediu m
Turb idity
P rogram 2
H igh Turbidity
P rogram 3
V ery High
Turb idity
P rogram 4
W a te r
Cla rity
Ad v a n ce d
P lu s
Co n tro lle r
C leaning
Sequence
D uratio n
A ppro ximate
Water
C onsumptio n
per C leaning
C ycle at 5 gpm
P ro gram 1
2 flushes
2.5 minutes
7.5 US Gal
P ro gram 2
4 flushes
6 minutes
15 US Gal
P ro gram 3
2 flushes and
1 drain
8.5 minutes
13.5 US Gal
P ro gram 4
2 flushes and
2 drains
16.5 minutes
19.5 US Gal
Advanced
P lus
C ontro ller
Summary of Contents for UFC 207
Page 23: ...23...