GE UFC 207 Owner'S Manual Download Page 10

10

Disconnect and
 Plug here

Outlet Fitting Assembly installed in standard
configuration shown. Systems equipped with the
Surface Water Option Kit have different Outlet
Fitting Assemblies.

For 

all Systems

 you will need:

Cap Wrench
Adjustable wrench
Nut driver
3 US gallons (12 litres) plumbers antifreeze that is

propylene glycol based 

and rated for -58 

o

F (-50 

o

C).

1-  ¾” MNPT PVC plug
1 -  ½” MNPT PVC plug

1

1

1

1

1

Close the Inlet Valve. Completely drain the System

and household piping.  To drain the System, refer to the

Controller Functions

 section under 

D. OPERATIONS 

on

how to perform a Manual Flush.  To drain the household
pipes, open a cold water  tap (on the lowest level of the
home) and leave until the tap only drips.  Turn off the tap
when the pipes are drained.

3

3

3

3

3

Drain the filtered water from the System by

disconnecting the Outlet Stainless Steel Flex Hose where
it connects to the home plumbing, and drain into a large
bucket.  Plug the Flex Hose and System by installing a ¾”
MNPT PVC plug.

F. WINTERIZATION PROCEDURE

4

4

4

4

4

If an External Prefilter has been installed, open the

Mini Ball Valve on the bottom of the housing and allow to
drain. Press the red button on the External Prefilter head
to speed up draining. Unscrew the housing from the
head and remove the External Prefilter cartridge from the
housing, and discard. Do not install a new filter cartridge.
Re-attach the filter housing to the head.

2

2

2

2

2

Remove the drain hose and Nylon Elbow from the

Drain Solenoid Valve and install a ½” MNPT or ¾” MNPT
PVC plug (depending on the size of the port) into the
Drain Solenoid Valve.

FIGURE 11

FIGURE 10

Tools/Supplies Required

Never use  AUTOMOTIVE  type antifreezes when
winterizing the System.  This may result in serious
injury or death.

Only plumbing antifreeze, consisting primarily of

propylene glycol

 with no ethanol or other alcohols,

rated for -58 

o

F (-50 

o

C),  may be used to winterize

the System. The use of less-expensive ‘non-
propylene glycol based’ plumbing or RV antifreezes
may damage the System’s internal components

voiding all warranties

.  This may also result in

serious injury or death.

Plumbing antifreeze containing 

propylene glycol

will provide protection of the System against
freezing to -40

 o

F  (-40 

o

C) as long as the proportion

of antifreeze to water is correct.   This procedure
only protects the System from freezing and does
not protect the rest of the household water
distribution system.

Propylene glycol

 based antifreeze is available at

most hardware stores.

WARNING!

All valves
closed

FIGURE 9

5

5

5

5

5

Remove the System Cap and remove the Prefilter.

If the System is equipped with the Carbon Prefilter,
discard the Carbon Prefilter.  If the System is equipped
with the Stainless Steel Prefilter, clean and set aside the
Stainless Steel Prefilter temporarily.  The Stainless Steel
Prefilter can be stored in the System for the winter in
Step 7.

FIGURE 12

Open

Summary of Contents for UFC 207

Page 1: ...Pages 13 to 14 H REPLACEMENT PART LIST AND PROCEDURES Pages 15 to 18 I SPECIFICATIONS Pages 19 to 20 J FAQ Pages 21 to 22 2006 V10 0 P N 23331 UFC 211 UFC 211 UFC 211 UFC 211 UFC 211 UF 211 UF 211 UF...

Page 2: ...dissertation on the principles set out above nor is it intended to be relied upon by anyone but Homespring Customer Care Consultants and Qualified Technicians Any other reliance is expressly excluded...

Page 3: ...do may result in System damage serious personal injury death and or property damage Use of non OEM parts will void the manufacturer s warranty The System is not intended for the treatment of water fro...

Page 4: ...nd Certified by NSF International against NSF ANSI 42 and 53 for Cyst Reduction Turbidity Reduction Particulate Reduction Class 1 System Tested and Certified by NSF International against NSF ANSI 42 a...

Page 5: ...even during a power failure Electricity is only required to activate the self cleaning sequences Normal Operation System Description Startup Information Sanitizing Information Setting the Controller...

Page 6: ...ect a Flush Drain Interval setting appropriate to the specific application Increase frequency of flush drain cycle if the System TMP rises too quickly Increasing the number of Flush Drain cycles per d...

Page 7: ...erform an Integrity Test to check the condition of the System membrane and perform a cleaning procedure to clean the System membrane This annual test and cleaning is mandatory as part of the 5 year li...

Page 8: ...ions in the Controller Functions section under D OPERATIONS on how to perform a Manual Flush sequence Slowly open the Mini Ball Valve to ensure there is no pressure in the System Water will flow out b...

Page 9: ...the flushing is complete open the Outlet Valve and a nearby COLD water tap to flush most of the chlorine from the System Run the tap fully open for at least 60 minutes Note Use only COLD water taps an...

Page 10: ...stall a new filter cartridge Re attach the filter housing to the head 2 2 2 2 2 Remove the drain hose and Nylon Elbow from the Drain Solenoid Valve and install a MNPT or MNPT PVC plug depending on the...

Page 11: ...eze water mix from the System into an empty container Add the remainder of the antifreeze into the Internal Prefilter cavity The fluid level in the System must be at least 2 above the bottom of the In...

Page 12: ...s If the System is on ground or well water the System must be cleaned with MC1 Cleaning Agent instead of chlorine bleach Follow the directions on the package for preparing the MC1 Cleaning Agent Never...

Page 13: ...ack cap on Air Relief Valve must be backed off by 1 5 turns from tight to allow air in and out of System Using the Controller initiate a manual flush sequence Refer to Controller Functions section und...

Page 14: ...ve Contact your Dealer to replace valve if necessary Inlet Solenoid Valve with Surface Water Option Kit Doesn t close to allow System to drain Does not open to allow flushing Check transformer is plug...

Page 15: ...may need to be washed or replaced prior to the Annual Maintenance A decrease in water pressure at the taps may indicate that the External Prefilter may need to be replaced Note For rinsing of the used...

Page 16: ...16 1 3 2 5 7 6 8 8 9 11 12 13 14 20 16 17 15 24 26 25 29 30 31 32 UFC 207 UF 207 UFC 209 UF 209 UFC 211 and UF 211 Series 18 FIGURE20 28 27 19 21 10 4 22 23...

Page 17: ...X 12 23154 System Cap Long X 13 23214 Loading O ring X X 14 23260 Kit Locking Clip with mounting screw X X 15 23159 System Base X X 16 23172 Thimble Filter X X 17 23221 Plug 1 4 NPT X X 18 23145 Serv...

Page 18: ...2 23090 External Prefilter O Ring X 3 23061 1 to Reducing Bushing X 4 23317 Inlet Solenoid Valve X 5 23054 Check Valve X 6 23137 Brass Closed Nipple X 7 23072 External Prefilter housing and head X 8...

Page 19: ...4 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres S y stem effic iency 87 94 92 96 94 97 Controller voltage 24 V A C 24 V A C 24 V A C Inlet port fem ale 3 4...

Page 20: ...ter use US gallons 15 gal 56 7 litres Program 3 2 flush backpulse cycles 1 drain cycle Estimated water use US gallons 13 5 gal 51 litres Program 4 2 flush backpulse cycles 2 drain cycles Estimated wat...

Page 21: ...the Carbon Prefilter are removed as the water passes from the outside of the Prefilter to the inside 2 The prefiltered water then passes down into the System to the membrane chamber 3 In the membrane...

Page 22: ...our water This includes calcium and magnesium which contribute to your hard water and other dissolved solids like essential minerals and flouride How long does the automatic cleaning cycle take Depend...

Page 23: ...23...

Reviews: