WARNING!

Operational

All System Parts and Components must be installed
in accordance with all local building and plumbing
codes.

The System must be installed on a cold-water supply
line only.  Failure to do so may cause System damage,
leading to personal injury and/or physical damage.

The System has been designed built and tested to
offer reliable service, provided if it is installed,
commissioned, operated, maintained and tested in
strict accordance with the instructions contained in
this manual. Failure to properly maintain the System
will compromise performance and/or result in a failure
to control water quality which may lead to delivery of
contaminated water. Consuming contaminated water
could result in serious injury or possibly death.

To avoid System damage, ensure that a Stainless
Steel Prefilter or Carbon Prefilter is in place during
operation of the System. Failure to do so 

will void all

warranties.

 In the absence of either filter, abrasive

damage to the System may occur.  A damaged
System may permit contaminated water to enter the
household distribution system causing illness or
death. Irreversible and premature fouling of the
System may also occur resulting in System
replacement at the owner’s expense.

Do not attempt to remove System
Cap when System is under
pressure.

The System must be kept wet at all times after
installation.  Do not let the System dry for longer than
12 hours.  Failure to do so may damage the System
causing personal injury, physical damage, illness
and/or death and 

will void all warranties

.

Premature fouling of the System is not covered by
the warranty. After the installation of the System if any
noticeable pressure drop occurs, call your local
Homespring Authorized Service Person.

Except in emergencies, do not open the Bypass
Valve (if applicable); Bypassing the System may
contaminate water supply and water supply system.

Always wash hands thoroughly with soap and water
after performing any servicing procedures on the
System.

Do not plug the Controller transformer in the electrical
receptacle if there is water on the electrical wiring or
on the power supply. Dry off all components first.

ONLY OEM

 parts supplied by the manufacturer are to

be used when installing or servicing the filtration
system (System). Failure to do may result in System
damage, serious personal injury, death and/or
property damage. Use of non-OEM parts will void the
manufacturer’s warranty.

The System is not intended for the treatment of water
from an obvious contamination source (such as
sewage or wastewater).

Biofilm and pathogens already present in home
piping lines downstream of the could migrate into
filtered water unless the piping has been properly
sanitized. All household piping and distribution lines
should be sanitized prior to consuming the filtered
water using proper sanitization procedures (see your
local Health authority). The System owner should verify
the water outlet quality at the outlet sources by having
it tested by an approved or qualified water testing
laboratory prior to consumption.

The System must be commissioned and maintained
in accordance with the Owner’s Manual by an
Authorized Service Person.  Failure to properly
maintain the System will compromise performance,
shorten the life of the System and may lead to delivery
of contaminated water. Consuming contaminated
water could result in serious injury or possibly death.

WARNING! 

Biological

If System is equipped with a Bypass Valve, do not
open Bypass Valve except in emergencies. Opening
the Bypass Valve will permit potentially microbially
contaminated water to enter the household water
distribution system. Drinking contaminated water may
cause serious illness and/or death. Do not drink the
water if the System has been operated in bypass
mode.

If the System has been operated in bypass mode
and if the water is being drawn from a well or surface
water source, the System and the household water
distribution system should be disinfected again once
returned to filtration mode.

If the System is in bypass mode, the Controller must
be unplugged.  Failure to do so may cause System to
dry and become damaged, leading to personal injury,
and/or physical damage and will 

void all warranties

.

A bypass is not required for proper operation of the
System. However, some local plumbing codes may
require a bypass. If a bypass is to be installed, the
procedure described below is to be followed in order
to provide water in an emergency or during System
malfunction.

Bypass Procedure

1.

Close Inlet and Outlet Valves. (If ball
valves are installed, turn the handles
perpendicular to the water pipe.)

2.

Open Bypass Valve (If ball valve is installed,
turn the handle in-line with the water pipe).

3.

Unplug Controller.

Emergency Bypass
Safety

WARNING!

Summary of Contents for UFC 207

Page 1: ...Pages 13 to 14 H REPLACEMENT PART LIST AND PROCEDURES Pages 15 to 18 I SPECIFICATIONS Pages 19 to 20 J FAQ Pages 21 to 22 2006 V10 0 P N 23331 UFC 211 UFC 211 UFC 211 UFC 211 UFC 211 UF 211 UF 211 UF...

Page 2: ...dissertation on the principles set out above nor is it intended to be relied upon by anyone but Homespring Customer Care Consultants and Qualified Technicians Any other reliance is expressly excluded...

Page 3: ...do may result in System damage serious personal injury death and or property damage Use of non OEM parts will void the manufacturer s warranty The System is not intended for the treatment of water fro...

Page 4: ...nd Certified by NSF International against NSF ANSI 42 and 53 for Cyst Reduction Turbidity Reduction Particulate Reduction Class 1 System Tested and Certified by NSF International against NSF ANSI 42 a...

Page 5: ...even during a power failure Electricity is only required to activate the self cleaning sequences Normal Operation System Description Startup Information Sanitizing Information Setting the Controller...

Page 6: ...ect a Flush Drain Interval setting appropriate to the specific application Increase frequency of flush drain cycle if the System TMP rises too quickly Increasing the number of Flush Drain cycles per d...

Page 7: ...erform an Integrity Test to check the condition of the System membrane and perform a cleaning procedure to clean the System membrane This annual test and cleaning is mandatory as part of the 5 year li...

Page 8: ...ions in the Controller Functions section under D OPERATIONS on how to perform a Manual Flush sequence Slowly open the Mini Ball Valve to ensure there is no pressure in the System Water will flow out b...

Page 9: ...the flushing is complete open the Outlet Valve and a nearby COLD water tap to flush most of the chlorine from the System Run the tap fully open for at least 60 minutes Note Use only COLD water taps an...

Page 10: ...stall a new filter cartridge Re attach the filter housing to the head 2 2 2 2 2 Remove the drain hose and Nylon Elbow from the Drain Solenoid Valve and install a MNPT or MNPT PVC plug depending on the...

Page 11: ...eze water mix from the System into an empty container Add the remainder of the antifreeze into the Internal Prefilter cavity The fluid level in the System must be at least 2 above the bottom of the In...

Page 12: ...s If the System is on ground or well water the System must be cleaned with MC1 Cleaning Agent instead of chlorine bleach Follow the directions on the package for preparing the MC1 Cleaning Agent Never...

Page 13: ...ack cap on Air Relief Valve must be backed off by 1 5 turns from tight to allow air in and out of System Using the Controller initiate a manual flush sequence Refer to Controller Functions section und...

Page 14: ...ve Contact your Dealer to replace valve if necessary Inlet Solenoid Valve with Surface Water Option Kit Doesn t close to allow System to drain Does not open to allow flushing Check transformer is plug...

Page 15: ...may need to be washed or replaced prior to the Annual Maintenance A decrease in water pressure at the taps may indicate that the External Prefilter may need to be replaced Note For rinsing of the used...

Page 16: ...16 1 3 2 5 7 6 8 8 9 11 12 13 14 20 16 17 15 24 26 25 29 30 31 32 UFC 207 UF 207 UFC 209 UF 209 UFC 211 and UF 211 Series 18 FIGURE20 28 27 19 21 10 4 22 23...

Page 17: ...X 12 23154 System Cap Long X 13 23214 Loading O ring X X 14 23260 Kit Locking Clip with mounting screw X X 15 23159 System Base X X 16 23172 Thimble Filter X X 17 23221 Plug 1 4 NPT X X 18 23145 Serv...

Page 18: ...2 23090 External Prefilter O Ring X 3 23061 1 to Reducing Bushing X 4 23317 Inlet Solenoid Valve X 5 23054 Check Valve X 6 23137 Brass Closed Nipple X 7 23072 External Prefilter housing and head X 8...

Page 19: ...4 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres S y stem effic iency 87 94 92 96 94 97 Controller voltage 24 V A C 24 V A C 24 V A C Inlet port fem ale 3 4...

Page 20: ...ter use US gallons 15 gal 56 7 litres Program 3 2 flush backpulse cycles 1 drain cycle Estimated water use US gallons 13 5 gal 51 litres Program 4 2 flush backpulse cycles 2 drain cycles Estimated wat...

Page 21: ...the Carbon Prefilter are removed as the water passes from the outside of the Prefilter to the inside 2 The prefiltered water then passes down into the System to the membrane chamber 3 In the membrane...

Page 22: ...our water This includes calcium and magnesium which contribute to your hard water and other dissolved solids like essential minerals and flouride How long does the automatic cleaning cycle take Depend...

Page 23: ...23...

Reviews: