GE UFC 207 Owner'S Manual Download Page 2

2

A. INTRODUCTION

B. SAFETY WARNINGS

It is important to read and understand the following safety
warnings to ensure reliable service from your System.

By purchasing the Homespring™ Water Purifier System,
you have taken the first step in providing safer, great
tasting water in the entire home.

The Homespring™ Water Purifier System (the System) is
an advanced Point of Entry (POE) water filtration system
that uses ultrafilter membrane technology to provide a
physical barrier to bacteria, parasites, viruses, and
particles. The System requires minimal maintenance and
will provide you with years of cleaner, safer, better tasting
water. Simply follow the information found in this manual
and schedule an annual maintenance visit with your
Homespring™ Dealer.

The System must be installed in strict compliance with
provincial or state laws and local laws and regulations.
The System conforms to ANSI/NSF 42 and 53 for the
specific performance claims as verified and substantiated
by test data. The System should only be used to filter
water less than 100

o

F (38

o

C) and must be protected from

freezing.

Thank You!

Legal Disclaimer

GE Water & Process Technologies

3239 Dundas Street West
Oakville, ON, Canada
L6M 4B2

www.homespring.com

Manufacturer’s Contact Information

This manual outlines some of the basic principles of
household water collection, treatment, and discharge and
some of the features of the 

Homespring™ Water Purifier

System

. It is not intended to be a definitive dissertation on

the principles set out above, nor is it intended to be relied
upon by anyone but 

Homespring™ Customer Care

(“Consultants”) and 

 Qualified Technicians

. Any other

reliance is expressly excluded.

The 

Homespring™ Water Purifier System

 must be

installed by a 

Homespring™ Authorized Technician

 and

properly maintained in accordance with the Operations
and the Owner’s Manual. Failure to properly maintain the
System will compromise performance and/or result in the
failure to control water quality.

Servicing Information

All service and maintenance must be performed by a
Homespring™ Authorized Technician. Should service be
required during or after the warranty period, or should you
have any questions regarding how to use your
Homespring™ Water Purifier System, please contact your
Homespring™ Dealer.

Read this manual carefully prior to using the
System.

Permanently locate this manual near the System
for future references.

Periodic checks of the System are required to
ensure safe and efficient operation.

Annual maintenance by a Homespring™

           Qualified Technician is required to validate the
             limited warranty.

Cost of all maintenance visits is the Owner’s
responsibility.

Most tools referenced in this manual are available
through your Homespring Dealer.

During servicing of the System, water supply in
your home will be temporarily interrupted.

IMPORTANT! - Read First

Dealer and System Information

Dealer’s Name

Dealer’s Phone Number

Model Number

Qualified Technician

Homespring™ Customer Service
Number 1-866-418-7412

Emergency Customer Service Number

Membrane Module Serial Number

Backpulse Tank Serial Number

Backpulse Tank Pressure Setpoint

Installation Date

Summary of Contents for UFC 207

Page 1: ...Pages 13 to 14 H REPLACEMENT PART LIST AND PROCEDURES Pages 15 to 18 I SPECIFICATIONS Pages 19 to 20 J FAQ Pages 21 to 22 2006 V10 0 P N 23331 UFC 211 UFC 211 UFC 211 UFC 211 UFC 211 UF 211 UF 211 UF...

Page 2: ...dissertation on the principles set out above nor is it intended to be relied upon by anyone but Homespring Customer Care Consultants and Qualified Technicians Any other reliance is expressly excluded...

Page 3: ...do may result in System damage serious personal injury death and or property damage Use of non OEM parts will void the manufacturer s warranty The System is not intended for the treatment of water fro...

Page 4: ...nd Certified by NSF International against NSF ANSI 42 and 53 for Cyst Reduction Turbidity Reduction Particulate Reduction Class 1 System Tested and Certified by NSF International against NSF ANSI 42 a...

Page 5: ...even during a power failure Electricity is only required to activate the self cleaning sequences Normal Operation System Description Startup Information Sanitizing Information Setting the Controller...

Page 6: ...ect a Flush Drain Interval setting appropriate to the specific application Increase frequency of flush drain cycle if the System TMP rises too quickly Increasing the number of Flush Drain cycles per d...

Page 7: ...erform an Integrity Test to check the condition of the System membrane and perform a cleaning procedure to clean the System membrane This annual test and cleaning is mandatory as part of the 5 year li...

Page 8: ...ions in the Controller Functions section under D OPERATIONS on how to perform a Manual Flush sequence Slowly open the Mini Ball Valve to ensure there is no pressure in the System Water will flow out b...

Page 9: ...the flushing is complete open the Outlet Valve and a nearby COLD water tap to flush most of the chlorine from the System Run the tap fully open for at least 60 minutes Note Use only COLD water taps an...

Page 10: ...stall a new filter cartridge Re attach the filter housing to the head 2 2 2 2 2 Remove the drain hose and Nylon Elbow from the Drain Solenoid Valve and install a MNPT or MNPT PVC plug depending on the...

Page 11: ...eze water mix from the System into an empty container Add the remainder of the antifreeze into the Internal Prefilter cavity The fluid level in the System must be at least 2 above the bottom of the In...

Page 12: ...s If the System is on ground or well water the System must be cleaned with MC1 Cleaning Agent instead of chlorine bleach Follow the directions on the package for preparing the MC1 Cleaning Agent Never...

Page 13: ...ack cap on Air Relief Valve must be backed off by 1 5 turns from tight to allow air in and out of System Using the Controller initiate a manual flush sequence Refer to Controller Functions section und...

Page 14: ...ve Contact your Dealer to replace valve if necessary Inlet Solenoid Valve with Surface Water Option Kit Doesn t close to allow System to drain Does not open to allow flushing Check transformer is plug...

Page 15: ...may need to be washed or replaced prior to the Annual Maintenance A decrease in water pressure at the taps may indicate that the External Prefilter may need to be replaced Note For rinsing of the used...

Page 16: ...16 1 3 2 5 7 6 8 8 9 11 12 13 14 20 16 17 15 24 26 25 29 30 31 32 UFC 207 UF 207 UFC 209 UF 209 UFC 211 and UF 211 Series 18 FIGURE20 28 27 19 21 10 4 22 23...

Page 17: ...X 12 23154 System Cap Long X 13 23214 Loading O ring X X 14 23260 Kit Locking Clip with mounting screw X X 15 23159 System Base X X 16 23172 Thimble Filter X X 17 23221 Plug 1 4 NPT X X 18 23145 Serv...

Page 18: ...2 23090 External Prefilter O Ring X 3 23061 1 to Reducing Bushing X 4 23317 Inlet Solenoid Valve X 5 23054 Check Valve X 6 23137 Brass Closed Nipple X 7 23072 External Prefilter housing and head X 8...

Page 19: ...4 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres S y stem effic iency 87 94 92 96 94 97 Controller voltage 24 V A C 24 V A C 24 V A C Inlet port fem ale 3 4...

Page 20: ...ter use US gallons 15 gal 56 7 litres Program 3 2 flush backpulse cycles 1 drain cycle Estimated water use US gallons 13 5 gal 51 litres Program 4 2 flush backpulse cycles 2 drain cycles Estimated wat...

Page 21: ...the Carbon Prefilter are removed as the water passes from the outside of the Prefilter to the inside 2 The prefiltered water then passes down into the System to the membrane chamber 3 In the membrane...

Page 22: ...our water This includes calcium and magnesium which contribute to your hard water and other dissolved solids like essential minerals and flouride How long does the automatic cleaning cycle take Depend...

Page 23: ...23...