GE UFC 207 Owner'S Manual Download Page 14

14

Area

Problem / Situation

Corrective Action / Remedy

External Prefilter 
(with Surface Water 
Option Kit)

Pres s  RED button on top of housing to releas e air until 
water flows  from  button as air m ay be trapped in hous ing.
Replace External Prefilter cartridge if water press ure has  
been gradually decreas ing as  the External Prefilter m ay 
be plugged or fouled.  Refer to 

L. REPLACEMENT PART 

LIST AND PROCEDURES

.

Water does  not flow through

Water leaks  from  bottom

Check Mini Ball Valve on bottom  of hous ing.  Clos e tightly.

Does not drain fas t enough

Controller

Check if the trans former is connected and plugged in.

Depres s red button on hous ing to drain quickly.

Drain Solenoid Valve

Using the Controller, initiate a manual flus h sequence.  
Refer to Controller Functions  s ection under 

D. 

OPERATIONS

 on how to perform  a m anual flus h 

s equence and ens ure button on controller is  pres s ed for 
a full 5 s econds .  A buzz sound s hould be heard from  the 
Drain Solenoid Valve.  Contact your Dealer to replace 
valve if neces sary.

Inlet Solenoid Valve 
(with Surface Water 
Option Kit)

Doesn't clos e to allow Sys tem  to 
drain

Does not open to allow flus hing

Check trans form er is  plugged in.

Check if the Drain Solenoid Valve functions .  Check 
connection to Controller is  correct and initiate a m anual 
flush to hear a buzz s ound.  Refer to 

Controller Functions 

under 

D. OPERATIONS

.

Contact your Dealer.

Check the s ettings .  Refer to 

Setting the Controller

 under 

D. OPERATIONS

.

Flus hing and/or draining of 
Sys tem  does  not work

Check if both the Inlet Solenoid Valve functions , if 
ins talled, and if the Drain Solenoid Valve functions .  On 
the Controller, pres s NEXT once.  Sim ultaneous ly pres s  
MANUAL FLUSH and the up arrow together and hold for a 
full 5 seconds .  A buzz s ound should be heard from both 
the Inlet and Drain Solenoid Valves .  Contact your Zenon 
Dealer if neces s ary.

On the Controller, press  NEXT once. Sim ultaneous ly 
pres s MANUAL FLUSH and the down arrow together and 
hold for a full 5 s econds . A buzz s ound s hould be heard 
from  the Inlet Solenoid Valve. Contact your Dealer to 
replace valve if neces sary.
Check trans form er is  plugged in.

Summary of Contents for UFC 207

Page 1: ...Pages 13 to 14 H REPLACEMENT PART LIST AND PROCEDURES Pages 15 to 18 I SPECIFICATIONS Pages 19 to 20 J FAQ Pages 21 to 22 2006 V10 0 P N 23331 UFC 211 UFC 211 UFC 211 UFC 211 UFC 211 UF 211 UF 211 UF...

Page 2: ...dissertation on the principles set out above nor is it intended to be relied upon by anyone but Homespring Customer Care Consultants and Qualified Technicians Any other reliance is expressly excluded...

Page 3: ...do may result in System damage serious personal injury death and or property damage Use of non OEM parts will void the manufacturer s warranty The System is not intended for the treatment of water fro...

Page 4: ...nd Certified by NSF International against NSF ANSI 42 and 53 for Cyst Reduction Turbidity Reduction Particulate Reduction Class 1 System Tested and Certified by NSF International against NSF ANSI 42 a...

Page 5: ...even during a power failure Electricity is only required to activate the self cleaning sequences Normal Operation System Description Startup Information Sanitizing Information Setting the Controller...

Page 6: ...ect a Flush Drain Interval setting appropriate to the specific application Increase frequency of flush drain cycle if the System TMP rises too quickly Increasing the number of Flush Drain cycles per d...

Page 7: ...erform an Integrity Test to check the condition of the System membrane and perform a cleaning procedure to clean the System membrane This annual test and cleaning is mandatory as part of the 5 year li...

Page 8: ...ions in the Controller Functions section under D OPERATIONS on how to perform a Manual Flush sequence Slowly open the Mini Ball Valve to ensure there is no pressure in the System Water will flow out b...

Page 9: ...the flushing is complete open the Outlet Valve and a nearby COLD water tap to flush most of the chlorine from the System Run the tap fully open for at least 60 minutes Note Use only COLD water taps an...

Page 10: ...stall a new filter cartridge Re attach the filter housing to the head 2 2 2 2 2 Remove the drain hose and Nylon Elbow from the Drain Solenoid Valve and install a MNPT or MNPT PVC plug depending on the...

Page 11: ...eze water mix from the System into an empty container Add the remainder of the antifreeze into the Internal Prefilter cavity The fluid level in the System must be at least 2 above the bottom of the In...

Page 12: ...s If the System is on ground or well water the System must be cleaned with MC1 Cleaning Agent instead of chlorine bleach Follow the directions on the package for preparing the MC1 Cleaning Agent Never...

Page 13: ...ack cap on Air Relief Valve must be backed off by 1 5 turns from tight to allow air in and out of System Using the Controller initiate a manual flush sequence Refer to Controller Functions section und...

Page 14: ...ve Contact your Dealer to replace valve if necessary Inlet Solenoid Valve with Surface Water Option Kit Doesn t close to allow System to drain Does not open to allow flushing Check transformer is plug...

Page 15: ...may need to be washed or replaced prior to the Annual Maintenance A decrease in water pressure at the taps may indicate that the External Prefilter may need to be replaced Note For rinsing of the used...

Page 16: ...16 1 3 2 5 7 6 8 8 9 11 12 13 14 20 16 17 15 24 26 25 29 30 31 32 UFC 207 UF 207 UFC 209 UF 209 UFC 211 and UF 211 Series 18 FIGURE20 28 27 19 21 10 4 22 23...

Page 17: ...X 12 23154 System Cap Long X 13 23214 Loading O ring X X 14 23260 Kit Locking Clip with mounting screw X X 15 23159 System Base X X 16 23172 Thimble Filter X X 17 23221 Plug 1 4 NPT X X 18 23145 Serv...

Page 18: ...2 23090 External Prefilter O Ring X 3 23061 1 to Reducing Bushing X 4 23317 Inlet Solenoid Valve X 5 23054 Check Valve X 6 23137 Brass Closed Nipple X 7 23072 External Prefilter housing and head X 8...

Page 19: ...4 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres 7 5 19 5 gal 28 4 73 7 litres S y stem effic iency 87 94 92 96 94 97 Controller voltage 24 V A C 24 V A C 24 V A C Inlet port fem ale 3 4...

Page 20: ...ter use US gallons 15 gal 56 7 litres Program 3 2 flush backpulse cycles 1 drain cycle Estimated water use US gallons 13 5 gal 51 litres Program 4 2 flush backpulse cycles 2 drain cycles Estimated wat...

Page 21: ...the Carbon Prefilter are removed as the water passes from the outside of the Prefilter to the inside 2 The prefiltered water then passes down into the System to the membrane chamber 3 In the membrane...

Page 22: ...our water This includes calcium and magnesium which contribute to your hard water and other dissolved solids like essential minerals and flouride How long does the automatic cleaning cycle take Depend...

Page 23: ...23...

Reviews: