System options
Table 20 below describes the System Options menu.
Table 20: System Options menu
Function Default
Description
RF jam detect
Off
Determines whether the panel checks for and reports RF
interference/jam to the central station (on), or not (off). If this
option is on and the panel receives a constant 319.5 MHz signal,
the panel reports the condition to the central station. If this
option is off, the panel does not detect an RF jam.
Demo mode
Off
Determines whether the panel operates as a demonstration
model (on) or a standard panel (off). Turning on this feature
disables low battery supervision and allows the microphone to
remain on continuously during an AVM session. With this option
on, the panel is not testing battery supervision.
HW1 function
1
Determines how the HW1 I/O output will function:
Off = no output
1 = interior siren output
2 = output activated when armed
3 = output activated when disarmed
4 = fail to communicate output, activates when fail to
communicate condition occurs (the fail to communicate option
must be on)
5 = alarm output activated when panel is in alarm
24-hour clock
Off
Determines whether the panel uses a 24-hour clock (on), or a 12-
hour clock (off).
Siren options
Table 21 below describes the Siren Options menu.
Table 21: Siren Options menu
Function Default
Description
Piezo beeps
On
Determines whether the panel piezo produces beeps based on
system activity (on), or is silent (off).
Panel voice
On
Determines whether the panel announces arming level changes
(on), or not (off).
Panel piezo alarm On
Determines whether the panel piezo emits alarm sounds (on), or
not (off).
38