Function Default
Description
Ring hang ring
1
Determines when the panel answers a remote phone access or
Enterprise call. Depending on whether an answering machine
exists at the panel location, offsite access to the panel can be done
with a series of phone calls or just one. For offsite access where an
answering machine does not exist, the user or Enterprise operator
simply calls the panel location once and listens for 10 rings. The
panel should answer after the tenth ring.
For offsite access where an answering machine exists, the user or
Enterprise operator must call the panel location, and then let the
phone ring once and hang up. Wait at least 10 seconds but not
more than 40, and then call the panel location again. The panel
should answer on the first ring.
Ring/hang/ring setting number and sequence of rings after which
the panel answers:
1 = Ring/hang/ring or ten rings
2 = Ring/hang/ring/hang/ring or ten rings
3 = Ring/hang/ring/hang/ring/hang/ring or ten rings
4 = Ten rings
5 = Ring/hang/ring
6 = Ring/hang/ring/hang/ring
7 = Ring/hang/ring/hang/ring/hang/ring
Off = Disabled, no remote (offsite) access
Dial delay
30 seconds
Determines whether the panel delays dialing programmed phone
numbers before sending report (on).
If opening (disarming) reports is on, the panel does not delay dialing
if the system is disarmed before the delay time expires. The panel
dials immediately for both the alarm and opening report.
Regardless of this option setting, the panel always dials
immediately for fire alarms, AC power failure, and low battery
reports.
Call wait code
Off
The call waiting code is dialed by the panel before a phone number
to disable call waiting. Verify that the end-user has call waiting with
his phone service provider before changing this option from its
default.
CAUTION: Changing this option from its default without call waiting
will prohibit the panel from calling the central station.
The call waiting code is programmed the same way as a dialer
number.
Line cut detect
Not available
30