– 66 –
Cooldown Chart
Cooldown is initiated to bring down the temperature of the microwave after a cook cycle has been
completed or the microwave has been paused. The chart below shows the length of time each fan is on
when a particular cook cycle has completed or has been paused.
Door
Status
Temp
Microwave
Broil & Toast Speedcook
Convection Warm Proof
Magnetron
Fan
Door
Open
>350°F
On for 3
mins.
On for 3
mins.
On for 3
mins.
On for 3
mins.
Off
Off
< 350°F
Off
On for 3
mins.
On for 3
mins.
On for 3
mins.
Off
Off
Door
Closed
>350°F
On for 3
mins.
On for 3
mins.
On for 3
mins.
On for 3
mins.
Off
Off
<350°F
Off
On for 3
mins.
On for 3
mins.
On for 3
mins.
Off
Off
Upper
Cooling
Motor
Door
Open
>350°F
Off
On for 5
mins.
On for 5
mins.
On for 5
mins.
Off
Off
<350°F
Off
On for 2
mins.
On for 2
mins.
On for 2
mins.
Off
Off
Door
Closed
>350°F
Off
On for 5
mins.
On for 5
mins.
On for 5
mins.
Off
Off
<350°F
Off
On for 2
mins.
On for 2
mins.
On for 2
mins.
Off
Off
Lower
Cooling
Motor
Door
Open
>350°F
On for 3
mins.
On for 5
mins.
On for 5
mins.
On for 5
mins.
Off
Off
<350°F
Off
On for 2
mins.
On for 2
mins.
On for 2
mins.
Off
Off
Door
Closed
>350°F
On for 3
mins.
On for 5
mins.
On for 5
mins.
On for 5
mins.
Off
Off
<350°F
Off
On for 2
mins.
On for 2
mins.
On for 2
mins.
Off
Off
Ventilation
Motor
Door
Open
>350°F
Off
On for 3
mins.
On for 3
mins.
On for 3
mins.
Off
Off
Door
Closed
<350°F
Off
On for 3
mins.
On for 3
mins.
On for 3
mins.
Off
Off