– 65 –
PL
0
No Element
1
275
Reaches temperature and then cycles at temperature for remainder of programmed
time.
2
285
Reaches temperature and then cycles at temperature for remainder of programmed
time.
3
295
Reaches temperature and then cycles at temperature for remainder of programmed
time.
4
305
Reaches temperature and then cycles at temperature for remainder of programmed
time.
5
315
Reaches temperature and then cycles at temperature for remainder of programmed
time.
6
325
Reaches temperature and then
cycles at 325°F for remainder of programmed time.
7
350
Reaches temperature and then
cycles at 325°F for remainder of programmed time.
8
375
Reaches temperature and then
cycles at 325°F for remainder of programmed time.
9
400
Reaches temperature and then
cycles at 325°F for remainder of programmed time.
10
425
Reaches temperature and then
cycles at 325°F for remainder of programmed time.
Power Level
0
1
2
3
4
5
6
7
8
9
10
On Time (Seconds.)
0
3.2
6.4
9.6
12.8
16.0
19.2
22.4
25.6
28.8
32.0
Off Time (Seconds.)
32.0
28.8
25.6
22.4
19.2
16.0
12.8
9.6
6.4
3.2
0
PL (Power Level) Chart
Convection PL Chart
The programming on the Smart Board which controls the upper halogen lamps (pair) and the lower ceramic
heater, as well as the high voltage/magnetron circuits, operates on a duty cycle of 32 seconds. This means
the power level you select for each component controls the percentage of ON time during each 32-second
period of time. For example, when the oven is set on power level 10, both the inner and outer halogen
heaters will stay on 100% of the time. On power levels less than 10, both heaters will cycle together. The
chart below shows on time verses off time for each power level setting.
Each convection power level setting directs the convection cooking system to operate within certain
parameters as shown in the table below.