– 23 –
Door Assembly
The door is available as a complete assembly or as
individual parts.
Pin
Pin
A microwave leakage test must be performed any
time a door is removed, replaced, disassembled, or
adjusted for any reason. The maximum leakage is 4
MW/CM
2
.
The Door Assembly utilizes permanently attached
upper and lower hinge pins. Each pin engages a
hole in each hinge arm attached to the oven.
To remove the door, rst remove the glass turntable,
then remove the Grill. (See
Grill
.) The door can then
be lifted up to disengage the door's upper and lower
hinge pins from the hinge arms protruding from the
oven.
(
Continued Next Page
)
To disassemble the door:
1. Place the door face down on a protective
surface.
2. Using a putty knife, carefully pry the choke cover
away from the door frame.
3. Remove the 5 Phillips-head screws from the
choke (3 on top, 1 each on bottom and latch
side).
4. Using
a
at blade screwdriver, disengage the
13 door frame retainers (4 each on top and
bottom, 3 on hinge pin side, and 2 on latch side).
Separate the door frame from the door panel.
Retainers (1 of 13)
Choke Cover
5. Using long nose pliers, remove the latch spring.
Slide and remove the latch from the choke.
Latch Spring
Latch