– 42 –
To remove the Humidity Sensor:
1. Remove the Outer Cover. (See
Outer Cover
.)
2. Remove the Air Tunnel Cover.
(See
Air Tunnel Cover
.)
3. Remove the 2 Phillips-head screws that hold the
sensor in place.
Humidity Sensor
Thermistor
• Location
(See
Right Side View
.)
• The upper thermistor (blue and white wires)
is used for thermal compensation and more
control in a higher temperature range (above
300°F) for Speed Cook, Broil, Toast, and
Convection.
• To test the upper thermistor, disconnect Smart
Board CN09. Check resistance between the
blue and white wires. Resistance at room
temperature is 100K ohm.
• The lower thermistor (red and white wires) is
used for more control in a lower temperature
range (below 300°F) and is used for Proof and
Warm.
• To test the lower thermistor, disconnect
Smart Board CN9. Check resistance between
the red and white wires. Resistance at room
temperature is 256K ohm.
To remove the Thermistor:
1. Remove the Outer Cover. (See
Outer Cover
.)
2. Remove the Phillips-head screw holding
Thermistor is place.