– 49 –
The convection heater
element is held in place
by 3 Phillips-head
screws. (Two screws on
the front, and 1 screw
on the end.)
End View of Element
Convection Heater
Convection Fan Motor
The convection fan must be removed before
removing the motor. The convection fan is held in
place by a 7-mm hex-head nut, lockwasher, and at
washer.
(
Continued Next Page
)
Front View of Outer Convection Fan
The Convection Fan Motor is attached to the motor
bracket with two 7-mm hex nuts. To access the hex
nuts, remove the 3 Phillips-head screws and the fan
motor bracket that is attached to the Convection
Heater Assembly.
Rear View of Convection Fan Motor
Convection Fan Motor
Fan Motor Bracket
Front View of Convection Fan Motor
Hex Nut
Hex Nut
Oven Lamp (Cavity)
• Location
(See
Top View
.
)
• Part of the
Oven Lamp (Cavity) Assembly
.
• 120
VAC
• 20
Watts
• Halogen
• For operating algorithms, see
Load Algorithm
Chart
.